Get Procommercial project · Seattle, WA
Commercial Electrical, Elevator, Hvac/Mechanical work permitted May 30, 2025, with 12 permits through June 15, 2026, declaring $105,564 of work. Contractor on record: Macdonald Miller Facility Solutions LLC.
INSTALL (1) SINGLE VALVE VAV BOX WITH LOW PRESSURE DUCT, DIFFUSERS, MEDIUM PRESSURE DUCT AND THERMOSTAT. INSTALL HYDRONIC PIPING FOR VAV INSTALL (1) SINGLE EXHAUST VALVE VAV BOX WITH LOW PRESSURE DUCT AND DIFFUSERS AIR BALANCE - SUBJECT TO FIELD INSPECTION (STFI)
Seattle permit records name Macdonald Miller Facility Solutions LLC, Empyrean dba Washington Elevator and Prime Electric as the contractors on this project, among 6 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
12 permits issued May 30 – Jun 15, newest first.
| Issued | Permit | Contractor |
|---|
Commercial and multifamily, biggest first.
| Value |
|---|
| applied Jun 15 | #7148002-EL Electrical · Electrical 645 Elliott Main Tripped - Job 1027003: Busway failed due to water intrusion, found some busway installed with drain holes up, all horizontal pieces will be checked and made sure to be installed correctly per note 4 on drawings. Damaged pieces removed. Manufacturer came out and retested existing… Status: Completed | Prime Electric | $29K |
#7137874-EL Electrical · Electrical BUSDUCT FAILURE, BRINGING IN A TEMP GENERATOR TO BLDG WHILE NEW SECTION CAN BE FOUND, PLACING PANELS ON FLOORS POWERED FROM GENERATOR THAT WILL BACKFEED THE EXISTING PANELS. 1ST FLOOR 800AMP FEEDER, 2ND FLOOR 400 & 800 AMP FEEDERS, 3RD FLOOR 800AMP FEEDER, 4TH FLOOR 400 & 800AMP FEEDERS, ALL AT… Status: Completed | Prime Electric | — | |
#7136580-EL Electrical · Electrical HVAC controls Status: Issued | Datskiy Electric LLC | — | |
| applied Mar 9 | #7130810-ME Mechanical · Trade INSTALL (1) SINGLE VALVE VAV BOX WITH LOW PRESSURE DUCT, DIFFUSERS, MEDIUM PRESSURE DUCT AND THERMOSTAT. INSTALL HYDRONIC PIPING FOR VAV INSTALL (1) SINGLE EXHAUST VALVE VAV BOX WITH LOW PRESSURE DUCT AND DIFFUSERS AIR BALANCE - SUBJECT TO FIELD INSPECTION (STFI) Status: Completed | Macdonald Miller Facility Solutions LLC | $42.3K |
| applied Sep 22 | #7107677-CY Conveyance · Trade Replacing the carpet in the elevators. EQP-SI-08195 / EQP-CY-07205 (2021 SBC = 2019 A17.1 = 2023 NEC/SEC = 2020 A18.1) Status: Issued | Empyrean dba Washington Elevator | $589 |
| applied Sep 22 | #7107675-CY Conveyance · Trade Replacing the carpet in the elevators with Fire 1 rated carpeting. EQP-SI-08195 / EQP-CY-07203 (2021 SBC = 2019 A17.1 = 2023 NEC/SEC = 2020 A18.1) Status: Issued | Empyrean dba Washington Elevator | $589 |
| applied Sep 22 | #7107676-CY Conveyance · Trade Replacing the carpet in the elevators. EQP-SI-08195 / EQP-CY-07204 (2021 SBC = 2019 A17.1 = 2023 NEC/SEC = 2020 A18.1) Status: Issued | Empyrean dba Washington Elevator | $589 |
#7103247-EL Electrical · Electrical Installation of AES radio to monitor FACP Status: Completed | Guardian Security Systems Inc | $750 | |
#7102989-EL Electrical · Electrical 438273 Load Bank Testing Only Status: Completed | OEG, Inc | $1.8K | |
#7094570-EL Electrical · Electrical INSTALL A CHW FAN COIL AT ROCHE DIAGNOSTICS TO SERVE IT/UPS ROOM Status: Completed | Macdonald Miller Facility Solutions LLC | $6K | |
| applied Jun 23 | #7092610-RF Refrigeration · Trade Install refrigeration piping for 3 ton DX ductless split system AC unit. Indoor evaporator unit located on 2nd floor and outdoor condensing unit located on P1 garage level. Status: Completed | Macdonald Miller Facility Solutions LLC | — |
| applied May 28 | #7083702-ME Mechanical · Trade INSTALL NEW HIGH EFFECIENCY SPLIT SYSTEM TO SERVE EXISTING 2ND FLOOR UPS ROOM AND RE-AIRBALANCE EXISTING VAV BOX, per plans Status: Completed | Macdonald Miller Facility Solutions LLC | $25.1K |
In Seattle, biggest first.