Get ProEvery project in every city · from $79/mo
Get Procommercial project · Seattle, WA
Commercial General Building, Electrical, Fire Protection, Hvac/Mechanical work permitted November 8, 2024, with 23 permits through September 23, 2026, declaring $649,686 of work. Contractor on record: Johnson Controls Fire Protection.
Tenant improvement to the north portion of level 2 of an existing 11-story office building for office use subject to field inspection STFI.
Seattle permit records name Johnson Controls Fire Protection, Cochran Inc and Prime Electric as the contractors on this project, among 5 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
23 permits issued Nov 8 – Sep 23, newest first.
| Issued | Permit | Contractor |
|---|
Commercial and multifamily, biggest first.
| Value |
|---|
#7163937-EL Electrical · Electrical 86285-installation of 30 amp breaker and receptacle Status: Issued | Cochran Inc | — | |
| applied Jul 9 | #7152068-CN Addition/Alteration · Building Construct Tenant Improvement Project at 1812 Boren Ave. Installing full height demountable partition wall subject to field inspection STFI. Status: Issued | Not published | $4K |
#7150781-EL Electrical · Electrical Modification to existing fire alarm system. Installation of (4) new devices on Level 9. Status: Issued | Johnson Controls Fire Protection | — | |
#7143722-EL Electrical · Electrical Amazon Sea 84.04.950 Reconfigure. Job 836820 Status: Issued | EC Electric | — | |
#7140921-EL Electrical · Electrical 84228- Install (1) 20 amp circuit for a receptacle on the 6th floor Status: Completed | Cochran Inc | — | |
| applied Mar 20 | #7133930-ME Mechanical · Trade Furnish and install (1) new VAV with electric heat. Includes associated duct. Status: Completed | Not published | $15K |
#7131960-EL Electrical · Electrical 81093_SEA84-Cochran to provide and install (1) Lambert and Fils CLI05BKBR_UL - Cliff Dome lighting fixture in breakout room 950 at SEA84. Site Contact: Ken Little Email: klittle@cochraninc.com Cell: 2065862051 Status: Completed | Cochran Inc | — | |
| applied Mar 3 | #7131796-CN Addition/Alteration · Building Construct tenant improvement project at 1812 Boren Ave to Install full height demountable partition wall STFI Status: Issued | Not published | $18.5K |
#7131275-EL Electrical · Electrical Modification to existing fire alarm system. Installation of (5) new devices on Lv 4/04.401 and 630 of the SEA84 Tilt 49 Building. Status: Issued | Johnson Controls Fire Protection | — | |
#7130989-FS Fire Sprinkler and Suppression · Trade Relocate 2 sprinklers to protect tenant improvements to walls. Status: Completed | Not published | $4.6K | |
| applied Nov 12 | #7116246-EL Electrical · Electrical Modify existing fire alarm system. Install (7) new fire alarm system devices and relocation of (1) device on floors 2, 4, 6, 7, 8, 9, 10, and 11 for phone booth installations. This is a joint venture between Johnson Controls Fire Protection (JOHNSCP831PR) and Prime Electric. Status: Completed | Johnson Controls Fire Protection | $15.7K |
#7112527-FS Fire Sprinkler and Suppression · Trade Add protection to 8 new phone booths installed over multiple floors. Status: Completed | Not published | $11K | |
| applied Aug 20 | #7102669-CN Addition/Alteration · Building Construct tenant improvement to office space to install phone booths subject to field inspection STFI Status: Completed | Not published | $160K |
#7101941-EL Electrical · Electrical Run electrical from the panel to the new water heater Status: Completed | McKinstry Co LLC | $15K | |
#7078890-EL Electrical · Electrical Modify existing fire alarm system for tenant improvements. Amazon SEA84 Tilt 49 - Lv 2 TI 1812 Boren Ave Seattle WA 98101. Install 4 new devices 4906-9254. This is a joint venture between Johnson Controls Fire Protection (JOHNSCP831PR) and Prime Electric (PRIMEES822BE). [4/7/2025 PGF Added (2)… Status: Completed | Johnson Controls Fire Protection | $10.8K | |
| applied Mar 12 | #7075066-FS Fire Sprinkler and Suppression · Trade TENANT IMPROVEMENT - ADD/RELOCATE FIRE SPRINKLERS FOR T.I. WALLS AND CEILINGS. PATRIFP099CF. (8) Heads. Status: Completed | Not published | $5.3K |
#7076469-EL Electrical · Electrical Job 4005500: Adding (1) general use duplex. Contact: Shawn Boulger 425-457-2224 Status: Completed | Prime Electric | $500 | |
#7076360-EL Electrical · Electrical Job 4005463: Adding (10) general use duplex receptacles. Lighting modifications as needed. Contact: Shawn Boulger 425-457-2224 Status: Completed | Prime Electric | $2.5K | |
| applied Mar 17 | #7075699-ME Mechanical · Trade Rework low-pressure distribution; relocate GRDs as required - Subject to Field Inspection (STFI) Status: Completed | Not published | $13K |
#7063849-EL Electrical · Electrical Modify existing fire alarm system for tenant improvements. SEA84 Level 2. Tilt 49 Office. 1812 Boren Ave Seattle WA 98101. Install (3) relocated devices and install (2) new speaker strobe devices (4906-9254). This is a joint venture between Johnson Controls Fire Protection (JOHNSCP831PR) and Prime… Status: Completed | Johnson Controls Fire Protection | $9.3K | |
#7059035-EL Electrical · Electrical Job 7011066: Install (3) new ceiling lights and (1) new exit sign. Add (6) new quads and (5) new duplex receptacles. Contact: Shawn Boulger 425-457-2224 Status: Completed | Prime Electric | $5.5K | |
#7056609-EL Electrical · Electrical JOB # 525921 - INSTALL (1) SECURITY PACKAGE FOR 84.09.209 Status: Completed | Not published | $17K | |
| applied Nov 8 | #7055375-CN Addition/Alteration · Building Tenant improvement to the north portion of level 2 of an existing 11-story office building for office use subject to field inspection STFI. Status: Completed | Not published | $357K |
In Seattle, biggest first.