Multifamily Electrical, Elevator, Fire Protection, Hvac/Mechanical, Sign work permitted May 12, 2025, with 37 permits through September 22, 2026, declaring $15,108,944 of work. Contractor on record: Schindler Elevator Corporation.
234 unit mixed use apt building
Seattle permit records name Schindler Elevator Corporation, Owp LLC and Emerald Aire, Inc. as the contractors on this project, among 13 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
37 permits issued May 12 – Sep 22, newest first.
| Issued | Permit | Contractor |
|---|
Commercial and multifamily, biggest first.
| Value |
|---|
#7163710-EL Electrical · Electrical 443378 NORTHGATE STATION - ONE CIRCUIT FOR DOORS. Status: Completed | OEG, Inc | — | |
| applied Sep 10 | #7160896-SB Sign, Awning and Canopy · Trade INSTALL SINGLE FACE ILLUMINATED WALL SIGN AND DOUBLE FACE ILLUMINATED PROJECTING SIGN Status: Issued | National Sign Corporation | $11.2K |
#7157166-EL Electrical · Electrical Installing limited energy wiring between floors for the trash chute on behalf of Independent Chute Company as requested by the Electrical Inspector Status: Issued | Haggard Electrical Contracting | — | |
#7153114-EL Electrical · Electrical Installing just the charger heads. Previous wiring and circuits already existing. 5 charging groups of 4 chargers each. 60 amp circuit per 4 chargers, controlled by Tesla software for power share. [C.Kenefick 7/15/206 - main electrical permit 7010393 reflects load calculations.] Status: Completed | EV Electric | — | |
| applied Jun 23 | #7149580-CY Conveyance · Trade Temp Use - Elev. #1 7088500-CY (Conveyance Installation Permit) 60-day temp use permit valid from date signed by City of Seattle elevator inspector. Must have two-way communication with operator at all times. Status: Completed | Schindler Elevator Corporation | $269K |
#7147011-EL Electrical · Electrical Pulling cat6 to (5) garage locations for network access points. Status: Completed | Region 6 Security | — | |
| applied May 21 | #7143912-CY Conveyance · Trade Install new traction elevator 1 - 11906025 6833919-CN (Construction Permit) 2018 SBC = 2020 SEC = 2019 A17.1 = 2017 A18.1 Status: Issued | Schindler Elevator | $226K |
| applied May 21 | #7143913-CY Conveyance · Trade Install new traction elevator 2 - 11906025 6833919-CN (Construction Permit) 2018 SBC = 2020 SEC = 2019 A17.1 = 2017 A18.1 Status: Issued | Schindler Elevator | $226K |
| applied May 21 | #7143917-CY Conveyance · Trade Install new traction elevator 3 - 11906024 6833919-CN (Construction Permit) 2018 SBC = 2020 SEC = 2019 A17.1 = 2017 A18.1 Status: Issued | Schindler Elevator | $226K |
| applied May 12 | #7141822-SB Sign, Awning and Canopy · Trade Fabricate and Install Exterior Signage: (2) Dimensional "E" on preinstalled plinth. (3) Under canopy channel letters "Everis". (2) "Parking". (2) Illuminated blade ID signs. (2) Above canopy channel letters "parking" w/ Spot Genius. (2) Circular parking "P" blade sign. (1) Wall mounted channel… Status: Issued | Waypoint Sign Company | $46K |
#7139763-EL Electrical · Electrical Provide and install (186) Low Voltage Maestro Thermostats, (20) Low Voltage Simple MA Thermostats, (2) Low Voltage EMR Thermostats, (4) Low Voltage Dampers and associated low voltage wiring. Status: Issued | Emerald Aire, Inc. | — | |
| applied Apr 23 | #7139760-RF Refrigeration · Trade Provide and install (8) outdoor heat pumps and associated refrigeration piping. Status: Issued | Emerald Aire, Inc. | $14.4K |
#7136241-EL Electrical · Electrical Provide and install (Qty 5) low voltage thermostats and (Qty 2) low voltage dampers and associated wiring per ASI 33. Status: Completed | Emerald Aire, Inc. | — | |
#7135373-FS Fire Sprinkler and Suppression · Trade Part of ongoing M2 project, the NE retail/restaurant area is being converted to a fitness center. Arm over sprinklers for large fans and drop pendents into new ceilings for restrooms/hall. Status: Completed | Fire Protection Systems, LLC | $4.5K | |
| applied Mar 20 | #7134433-CY Conveyance · Trade Temp Use - Elev. #1 7088500-CY (Conveyance Installation Permit) 60-day temp use permit valid from date signed by City of Seattle elevator inspector. Must have two-way communication with operator at all times. Status: Completed | Schindler Elevator | $269K |
#7133562-EL Electrical · Electrical Installing limited energy wiring between floors for the trash chute on behalf of Independent Chute Company as requested by the Electrical Inspector Status: Completed | Haggard Electrical Contractors | — | |
#7131783-EL Electrical · Electrical Installation of rooftop Solar Photovoltaic System Consisting of 16.24kW DC / 11.96kW AC. (28) Silfab SIL_580_XM+. (28) Enphase IQ9N-3P-277-A-DOM-US. Status: Issued | Puget Sound Solar | — | |
| applied Oct 20 | #7112284-FS Fire Sprinkler and Suppression · Trade THIS PROJECT CONSISTS OF THE INSTALLATION OF NEW WET AND DRY SPRINKLER SYSTEMS, WITH AN ELECTRIC FIRE PUMP, ALONG WITH 3 CLASS 1 STANDPIPES, DESIGNED AND INSTALLED IN ACCORDANCE WITH 2019 NFPA 13, 14, 20, 2021 IFC & IBC, AS WELL AS LOCAL JURISDICTION SPECIFICATIONS/GUIDELINES. Status: Issued | Not published | $611K |
| applied Jun 6 | #7089440-EL Electrical · Electrical INSTALLATION OF A NEW MANUAL AND AUTOMATIC FIRE ALARM SYSTEM IN A NEW BUILDING. NEW FIRE ALARM PANEL IS BEING INSTALLED ALONG WITH NOTIFICATION DEVICES AS PER THE APPLICABLE CODES. SPRINKLER WATERFLOW SWITCH IS BEING MONITORED TO ACTIVATE NOTIFICATION DEVICES UPON ALARM 7/29/25 Get Started… Status: Issued | Haggard Electrical Contractors | $482K |
| applied Jan 21 | #7125781-CY Conveyance · Trade Temp Use - Elev. #1 7088500-CY (Conveyance Installation Permit) 60-day temp use permit valid from date signed by City of Seattle elevator inspector. Must have two-way communication with operator at all times. Status: Completed | Schindler Elevator Corporation | $269K |
#7122428-BP Boiler/Pressure Vessel · Trade 234 unit mixed use apt building Status: Completed | Owp LLC | $6M | |
#7122431-BP Boiler/Pressure Vessel · Trade Hot Water Supply Boiler. No Decarb plan required. Status: Completed | Owp LLC | $6M | |
#7122434-BP Boiler/Pressure Vessel · Trade 234 unit multi family apt building Status: Completed | Owp LLC | $6M | |
#7122436-BP Boiler/Pressure Vessel · Trade 234 unit mixed use apt building Status: Completed | Owp LLC | $6M | |
#7122438-BP Boiler/Pressure Vessel · Trade 234 unit mixed use apt building Status: Completed | Owp LLC | $6M | |
#7122441-BP Boiler/Pressure Vessel · Trade 234 unit mixed use apt building Status: Completed | Owp LLC | $6M | |
#7120413-EL Electrical · Electrical PS DAS system for new construction mixed use building Status: Issued | Haggard Electrical Contractors | $110K | |
| applied Sep 2 | #7104653-EL Electrical · Electrical CONSTRUCTION OF ONE NEW MIXED-USE APARTMENT BUILDING CONSISTING OF 186 APARTMENT UNITS ON 4-5 LEVELS ABOVE GROUND LEVEL SHELL RETAIL SPACES AND 2 BELOW GRADE DAYLIGHT BASEMENT LEVELS. TYPE OF CONSTRUCTION FOR THE UPPER 4-5 STORIES IS TYPE V-A. TYPE OF CONSTRUCTION FOR THE LEVELS BELOW THE 3-HR… Status: Issued | Haggard Electrical Contractors | $4.9M |
| applied Nov 13 | #7115770-CY Conveyance · Trade install a traction elevator #4 6839217-PH (Phased Construction Permit) 2021 SBC = 2019 A17.1 = 2023 NEC/SEC = 2020 A18.1 Status: Completed | Schindler Elevator Corporation | $189K |
#7106350-EL Electrical · Electrical Cabling and installation of the following AV products in new construction: 1. Televisions: 65" TV in meeting room with SmartVision Sound bar and wireless microphone unit - 75" TV in East lobby area - 85" TV with Sonos soundbar in Clubhouse. 2. Speakers - 31 speakers to include 25V and 8 Ohm… Status: Issued | Region 6 Security Integration | $101K | |
| applied Jun 25 | #7032367-FS Fire Sprinkler and Suppression · Trade Multiuse Apartment project and parking ramp - fire sprinklers, fire pump, standpipes. Status: Completed | Fire Protection Systems, LLC | $1.6M |
#7094855-EL Electrical · Electrical PS DAS system for a new construction mixed use building Status: Completed | Haggard Electrical Contractors | $256K | |
| applied Jun 9 | #7089900-CY Conveyance · Trade install a traction elevator 6839217-PH (Phased Permit) (2018 SBC=2020 SEC=2019 A17.1=2017 A18.1) Status: Completed | Schindler Elevator Corporation | $256K |
| applied May 30 | #7088502-CY Conveyance · Trade Install a traction elevator 6839217-PH (2018 SBC=2020 SEC=2019 A17.1=2017 A18.1) Status: Completed | Schindler Elevator Corporation | $269K |
| applied May 30 | #7088500-CY Conveyance · Trade install a traction elevator 6839217-PH (2018 SBC=2020 SEC=2019 A17.1=2017 A18.1) Status: Completed | Schindler Elevator Corporation | $269K |
#7085299-EL Electrical · Electrical Provide and install (15) low voltage thermostats in common spaces, (7) low voltage ERV controllers, (13) low voltage dampers, (222) low voltage thermostats in living units and associated wiring. Status: Completed | Emerald Aire, Inc. | $38.5K | |
| applied May 12 | #7085298-RF Refrigeration · Trade Provide and install (6) outdoor heat pumps and associated refrigeration piping. mechanical is under permit 6839217-PH Status: Completed | Emerald Aire, Inc. | $10.8K |