Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted June 4, 2026, with 4 permits through July 16, 2026. Contractor on record: MK Fire Protection & Supply, LLC.
Get new commercial permits near 19130 or Philadelphia, free weekly email
FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13R TO ACCOMMODATE THE 3RD AND 4TH FLOOR OF AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 2" FIRE SERVICE LINE AND 2" DC WILKINS 950 XLT2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.
Philadelphia permit records name MK Fire Protection & Supply, LLC, Eagle Electrical Construction Co Inc and Sanks Mechanical as the contractors on this project, among 4 contractors in all.
The property owner is included with Pro.
4 permits issued Jun 4 – Jul 16, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#FP-2026-001152 Fire Suppression Permit · New Construction FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13R TO ACCOMMODATE THE 3RD AND 4TH FLOOR OF AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 2" FIRE SERVICE LINE AND 2" DC WILKINS 950 XLT2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A… Status: Completed | MK Fire Protection & Supply, LLC | — | |
#EP-2026-004440 Electrical Permit · Addition and/or Alteration INSTALL 1200 AMP ELECTRICAL SERVICE, METER SOCKETS AND CIRCUIT BREAKER PANELS WITH PROPER GROUNDING AND BONDING. REWIRE THE 4 DWELLING UNITS THROUGHOUT AND INSTALL LIGHTING, SWITCHES, EXIT SIGNS, EMERGENCY LIGHTING AND RECEPTACLE OUTLETS. INSTALL 120 VOLTS INTERCONNECTED SMOKE AND CO ALARMS.… Status: Completed | Eagle Electrical Construction Co Inc | — | |
#MP-2026-003181 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO… Status: Completed | Sanks Mechanical | — | |
#PP-2026-006807 Plumbing Permit · Alterations ALTERATION TO CREATE 4 NEW DWELLING UNITS OUT OF 2 UNITS IN MUTLI-FAMILY BUILDING. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE… Status: Completed | Plumetrix Inc | — |
In Philadelphia, biggest first.