Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted January 12, 2026, with 8 permits through July 14, 2026. Contractor on record: Total Comfort Solutions.
Get new commercial permits near 19139 or Philadelphia, free weekly email
FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, BATHROOM AND CLOTHES DRYER EXHAUSTS, AND ASSOCIATED DUCTWORK THROUGHOUT A MULTI-FAMILY BUILDING AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. SEE CP-2025-001526 FOR ASSOCIATED BUILDING PERMIT.
Philadelphia permit records name Total Comfort Solutions, Madden Electric Associates, Inc and MK Fire Protection & Supply, LLC as the contractors on this project, among 6 contractors in all.
The property owner is included with Pro.
8 permits issued Jan 12 – Jul 14, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#MP-2025-006396 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, BATHROOM AND CLOTHES DRYER EXHAUSTS, AND ASSOCIATED DUCTWORK THROUGHOUT A MULTI-FAMILY BUILDING AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN… Status: Issued | Total Comfort Solutions | — | |
#EP-2026-002778 Electrical Permit · New Construction INSTALL 1200 AMP SERVICE WITH GROUNDING. INSTALL LIGHTING, RECEPTACLES, SMOKE/CO ALARMS, FIRE PUMP WIRING, TELECOMMUNICATIONS WIRING, AND PROVIDE POWER TO EQUIPMENT AS PER 2017 NEC. INSTALL FIRE ALARM AS PER 2016 NFPA 72. Status: Issued | Madden Electric Associates, Inc | — | |
#FP-2025-002514 Fire Suppression Permit · New Construction TO INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 4" MAIN FIRE SERVICE LINE WITH 4" AMES COLT 200 BACKFLOW PREVENTION ASSEMBLY AND FIRE SYSTEM TO INCLUDE FIRE PUMP IN ACCORDANCE WITH NFPA 20 AND THE INSTALLATION OF TWO (2) STANDPIPES IN EXIT… Status: Issued | MK Fire Protection & Supply, LLC | — | |
#PP-2025-015546 Plumbing Permit · New Construction or Additions All sanitary,storm and domestic water piping to a point of 5 feet ouside of building.All fixtures and piping to include 44-WC, 44-Lavatory, 21- bath tubs, 12 SHW, 35 Kitchen Sinks, 33-Washer Boxes, 40-EWH, 1-SP-1, 1-SP-2, 36 FD, 1- Area Drain, 6- Wall Hydrant, 2 Hose bib, 4 Mop receptors,… Status: Issued | BBJ Mechanical Inc | — | |
#PP-2026-003173 Plumbing Permit · New Construction or Additions INSTALL SANITARY AND STORM CT's, FAI's, MD's & 2" WDP. Status: Issued | Carso Construction LLC | — | |
#MP-2025-006129 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE… Status: Issued | Total Comfort Solutions | — | |
#EP-2026-000965 Electrical Permit · New Construction 200 Amp Temporary Service for construction site. All work to be done according to the 2017 NEC. Status: Completed | Madden Electric Associates, Inc | — | |
#SP-2025-000886 Site / Utility Permit · Excavation Site / Utility Permit for CP-2025-001526 Status: Issued | Athena Contracting Inc | — |
In Philadelphia, biggest first.