Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted June 26, 2025, with 7 permits through May 1, 2026. Contractor on record: Wm A J Shaeffer & Sons.
Get new commercial permits near 19104 or Philadelphia, free weekly email
Provide and install 1,041 Cat6A plenum cables at 175' a average. Provide and install 50 wireless access point locations consisting of 1 Cat6A plenum cable at 150' average. All work will be completed per 2017 NEC. No rescue systems work.
Philadelphia permit records name Wm A J Shaeffer & Sons, Lanconnect Inc and Oliver Sprinkler Co., Inc. as the contractors on this project, among 6 contractors in all.
The property owner is included with Pro.
7 permits issued Jun 26 – May 1, newest first.
| Issued | Permit |
|---|
Commercial and multifamily, biggest first.
| Contractor |
|---|
| Value |
|---|
#EP-2026-003129 Electrical Permit · Addition and/or Alteration Provide and install 1,041 Cat6A plenum cables at 175' a average. Provide and install 50 wireless access point locations consisting of 1 Cat6A plenum cable at 150' average. All work will be completed per 2017 NEC. No rescue systems work. Status: Issued | Lanconnect Inc | — | |
#EP-2026-000050 Electrical Permit · New Construction Provide new fire alarm system. Includes new fire alarm panel, devices and wire. ALL WORK IS TOBE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72. Status: Issued | Wm A J Shaeffer & Sons | — | |
#FP-2025-002062 Fire Suppression Permit · Addition and/or Alterations FOR THE INSTALLATION OF 599 RELIABLE SPRINKLERS AND STANDPIPE TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING USING THE EXISTING 8" FIRE WATER SUPPY LINE, FIRE PUMP AND BACK FLOW PREVENTER. AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE… Status: Issued | Oliver Sprinkler Co., Inc. | — | |
#EP-2025-005553 Electrical Permit · New Construction Provide new electrical construction for a proton center at Penn Presbyterian Hospital. Will consist of installation of a new 480v substation, 1 emergency switchboard, 1 generator, 24 panelboards, lighting, receptacles, and nurse call as per 2017 NEC. Fire alarm will be applied for at a later date. Status: Issued | Wm A J Shaeffer & Sons | — | |
#MP-2025-004039 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO… Status: Issued | Aerdux Inc | — | |
#PP-2025-010011 Plumbing Permit · New Construction or Additions REPAIR/REPLACE CT, FAI & MD. Status: Completed | Harry J Stuhl III | — | |
#PP-2025-007193 Plumbing Permit · New Construction or Additions New water piping, waste piping, plumbing fixtures and storm water piping for an addition to hospital Status: Issued | Herman Goldner Co Inc | — |
In Philadelphia, biggest first.