Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted February 5, 2026, with 5 permits through May 18, 2026. Contractor on record: Eagle Electrical Construction Co Inc.
Get new commercial permits near 19146 or Philadelphia, free weekly email
Install 300 amp service equipment and grounding. Wiring throughout the building. Install light fixtures, outlets, switches, smoke/CO alarms, emergency lights, and exit signs as per 2017 NEC. Install fire alarm system as per 2016 NFPA 72.
Philadelphia permit records name Eagle Electrical Construction Co Inc, Nazar Home Construction Inc and Plumetrix Inc as the contractors on this project, among 5 contractors in all.
The property owner is included with Pro.
5 permits issued Feb 5 – May 18, newest first.
| Issued |
|---|
Commercial and multifamily, biggest first.
| Permit |
|---|
| Contractor |
|---|
| Value |
|---|
#EP-2026-003402 Electrical Permit · New Construction Install 300 amp service equipment and grounding. Wiring throughout the building. Install light fixtures, outlets, switches, smoke/CO alarms, emergency lights, and exit signs as per 2017 NEC. Install fire alarm system as per 2016 NFPA 72. Status: Issued | Eagle Electrical Construction Co Inc | — | |
#MP-2026-001999 Mechanical / Fuel Gas Permit · New Construction **2021 IMC REVIEW** FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF… Status: Issued | Nazar Home Construction Inc | — | |
#PP-2026-001766 Plumbing Permit · New Construction or Additions new plumbing system for triplex including 5 tub/shower 3 kitchen sinks 3 water heaters 3 washer boxes 5 lavatories 3 laundry sinks 5 water closets Status: Issued | Plumetrix Inc | — | |
#PP-2026-002357 Plumbing Permit · New Construction or Additions INSTALL SANITARY AND STORM CTs, FAIs, MD & 1.5” WATER DISTRIBUTION PIPE. Status: Completed | Thomas Uhl | — | |
#FP-2026-000128 Fire Suppression Permit · New Construction FOR THE INSTALLATION OF A 2-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A 2 INCH WILKINS 950XLT2 BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH NFPA 13R. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. Status: Issued | Michael J Mccullough jr | — |