Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted September 11, 2025, with 6 permits through November 24, 2025. Contractor on record: On Point Plumbing LLC.
Get new commercial permits near 19146 or Philadelphia, free weekly email
FOR INSTALLATION OF FOUR-INCH FIRE SERVICE LINE, FOUR-INCH BACKFLOW PREVENTER AND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13.
Philadelphia permit records name On Point Plumbing LLC, Charles G. Hunter III and B.H. HOLDINGS CORP ( Emergency Response Associates) as the contractors on this project, among 5 contractors in all.
The property owner is included with Pro.
6 permits issued Sep 11 – Nov 24, newest first.
| Issued |
|---|
Commercial and multifamily, biggest first.
| Permit |
|---|
| Contractor |
|---|
| Value |
|---|
#FP-2025-002180 Fire Suppression Permit · New Construction FOR INSTALLATION OF FOUR-INCH FIRE SERVICE LINE, FOUR-INCH BACKFLOW PREVENTER AND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13. Status: Completed | Charles G. Hunter III | — | |
#PP-2025-013587 Plumbing Permit · Alterations Scope of work: existing Planet Fitness space - Plumber to do the 2” water tap at the street and bring it into the building. For the 4” sprinkler tap – PDW will bring it from the street to the curb stop. our plumber will connect from there. Pre-app #33767 (2” D.S.) Pre-app #33768 (4” F.C.)… Status: Completed | On Point Plumbing LLC | — | |
#EP-2025-008907 Electrical Permit · Addition and/or Alteration INSTALLATION OF FIRE ALARM SYSTEM AS PER 2016 NFPA 72. TWO RELAY MODULE TO SHUT DOWN NEW FANS. FOUR RELAYS FOR ELEVATORS INTERFACE FOR RECALLS AS PER CODE. TWO MONITOR MODULES FOR WATERFLOW AND TAMPER SWITCH. WEATHER PROOF HORN/STROBE TIE THROUGH FLOW SWITCH. Status: Completed | B.H. HOLDINGS CORP ( Emergency Response Associates) | — | |
#EP-2025-007501 Electrical Permit · Addition and/or Alteration Electrical Permit for combo CP-2025-003492: Install lighting, switches, lighting controls, exit/emergency lighting, receptacles, telecommunication wiring and power to equipment as per 2017 NEC. ***NOT APPROVED FOR THE INSTALLATION OF FIRE ALARM*** Status: Completed | Crivello Electric, Inc | — | |
#PP-2025-009968 Plumbing Permit · Alterations Plumbing Permit (Interior) for combo CP-2025-003492- plumbing per plans. Status: Completed | On Point Plumbing LLC | — | |
#MP-2025-004066 Mechanical / Fuel Gas Permit · Addition and/or Alterations Mechanical / Fuel Gas Permit for combo CP-2025-003492 Status: Completed | Futuro Construction Inc. | — |
In Philadelphia, biggest first.