Get Procommercial project · Philadelphia, PA
Commercial Fire Protection, Hvac/Mechanical, Plumbing work permitted January 25, 2026, with 4 permits through May 4, 2026. Contractor on record: Apex Mechanical Inc.
Get new commercial permits near 19123 or Philadelphia, free weekly email
AMENDMENT 10/17/2026 CHANGE IN BACKFLOW PREVENTION ASSEMBLY MODEL AMENDMENT 8/11/2026 CHANGE IN INSTALLED MATERIALS IN BASEMENT SPACE. MATERIALS SPECIFIED ON PLANS TO BE CAST IRON. AMENDMENT 6/8/2026 REVISIONS TO MATERIAL SCHEDULE. NEW CONSTRUCTION OF MIXED USE BUILDING. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL MATERIALS SHALL BE METALLIC TO ROOF EXTENSION FOR PIPING SERVING COMMERCIAL SPACE. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE…
Philadelphia permit records name Apex Mechanical Inc, Sanks Mechanical and Harring Fire Protection, LLC as the contractors on this project, among 4 contractors in all.
The property owner is included with Pro.
4 permits issued Jan 25 – May 4, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#PP-2026-001386 Plumbing Permit · New Construction or Additions AMENDMENT 10/17/2026 CHANGE IN BACKFLOW PREVENTION ASSEMBLY MODEL AMENDMENT 8/11/2026 CHANGE IN INSTALLED MATERIALS IN BASEMENT SPACE. MATERIALS SPECIFIED ON PLANS TO BE CAST IRON. AMENDMENT 6/8/2026 REVISIONS TO MATERIAL SCHEDULE. NEW CONSTRUCTION OF MIXED USE BUILDING. INTERIOR INSTALLATION OF… Status: Issued | Apex Mechanical Inc | — | |
#MP-2025-004401 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO… Status: Issued | Sanks Mechanical | — | |
#FP-2026-000075 Fire Suppression Permit · New Construction FOR INSTALLATION OF A FOUR-INCH FIRE SERVICE LINE, FOUR-INCH BACKFLOW PREVENTER, FIRE SPRINKLER SYSTEM AND STANDPIPES PER APPROVED PLANS, HYDRAULIC CALCULATIONS, NFPA 13 AND NFPA 14. Status: Issued | Harring Fire Protection, LLC | — | |
#PP-2025-016100 Plumbing Permit · New Construction or Additions INSTALL SANITARY AND STORM CT's, FAI's, MD's & 2" WDP. Status: Completed | Charles Cohen | — |