Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted July 7, 2025, with 5 permits through September 25, 2025. Contractor on record: Apex Mechanical Inc.
Get new commercial permits near 19125 or Philadelphia, free weekly email
INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 4" MAIN FIRE SERVICE LINE WITH 4-INCH WILKINS 350AST BACKFLOW PREVENTER AND AUTOMATIC FIRE SUPPRESSION SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.
Philadelphia permit records name Apex Mechanical Inc, B M Consulting Services Inc and Al-Kaun Co as the contractors on this project, among 4 contractors in all.
The property owner is included with Pro.
5 permits issued Jul 7 – Sep 25, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#FP-2025-001883 Fire Suppression Permit · Addition and/or Alterations INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 4" MAIN FIRE SERVICE LINE WITH 4-INCH WILKINS 350AST BACKFLOW PREVENTER AND AUTOMATIC FIRE SUPPRESSION SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER… Status: Issued | B M Consulting Services Inc | — | |
#PP-2025-008613 Plumbing Permit · Alterations INTERIOR ALTERATIONS TO EXISTING BUILDING AS SPECIFIED: The scope of work for this project is for the installation of all subgrade sanitary waste & vent piping, installation of the stormwater system, and the delivery of a domestic water service to the building. A plumbing fixture schedule has been… Status: Completed | Apex Mechanical Inc | — | |
#MP-2025-003730 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF ROOF TOP UNIT APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE… Status: Issued | Al-Kaun Co | — | |
#EP-2025-005815 Electrical Permit · Addition and/or Alteration Installing a 400 ampere a 3 phase delta service and a 400 ampere single phase service only!. Also installing addressable fire alarm system throughout building. All work to be done according to the 2017 NEC and the 2016 NFPA 72 and per plans. Status: Completed | Sal Cascio | — | |
#PP-2025-008610 Plumbing Permit · Alterations Install 2" domestic water service, storm and sanitary curb traps complete with fresh air inlets and main house drains. Status: Completed | Apex Mechanical Inc | — |