Commercial General Building, Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted February 25, 2026, with 5 permits through October 22, 2026. Contractor on record: Sanks Mechanical.
Get new commercial permits near 19133 or Philadelphia, free weekly email
Install 400A main service with 5 gang meter module. Install all wiring throughout 4 apartments and common areas. Install fire alarm system,110V INTERCONNECTED SMOKE ALARMS. Install low voltage wiring for cable tv. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
Philadelphia permit records name Sanks Mechanical, Ak Scorpion Inc and B M Consulting Services Inc as the contractors on this project, among 4 contractors in all.
The property owner is included with Pro.
Commercial and multifamily, biggest first.
5 permits issued Feb 25 – Oct 22, newest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#EP-2026-003566 Electrical Permit · New Construction Install 400A main service with 5 gang meter module. Install all wiring throughout 4 apartments and common areas. Install fire alarm system,110V INTERCONNECTED SMOKE ALARMS. Install low voltage wiring for cable tv. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72. Status: Issued | Contractor with Pro | — | |
#MP-2026-004641 Mechanical / Fuel Gas Permit · New Construction **2021 IMC REVIEW** FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF… Status: Issued | Sanks Mechanical | — | |
#PP-2026-009265 Plumbing Permit · New Construction or Additions Interior and Exterior 12 Toilets 8 Shower tub 12 sink 4 Kitchen 4 Laundry 2 Hose bibbs 2 Sump pump 4 water heater NEW CONSTRUCTION OF 4 DWELLING BUILDING. EXTERIOR INSTALLATION OF CURB TRAP, FAI, MAIN DRAIN, AND 1" WATER DISTRIBUTION PIPE. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER… Status: Issued | Ak Scorpion Inc | — | |
#FP-2026-001121 Fire Suppression Permit · New Construction INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE WITH A 2" WILKINS 950XLT2BFSS BACKFLOW PREVENTION ASSEMBLY PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. Status: Issued | B M Consulting Services Inc | — | |
#SP-2025-000177 Site / Utility Permit · Excavation Site / Utility Permit for CP-2024-006587 FOR EXCAVATION AND BACKFILL OF SITE AND INSTALLATION OF RELATED STABILIZATION MEASURES. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. **… Status: Issued | Ar Demolition Inc | — |