Get ProEvery project in every city · from $79/mo
Get Procommercial project · Minneapolis, MN
Commercial General Building, Hvac/Mechanical, Plumbing work permitted June 23, 2025, with 6 permits through June 9, 2026, declaring $6,073,079 of work. Contractor on record: B and D Plumbing Heating and A/C Inc.
2ND STORY GYM ADDITION. BUILDING D. 2ND FLOOR IS 55,050 SF. (JJL) certificate of occupancy required yes no special inspections required yes AMERICAN ENGINEERING TESTING const type: IB occupancy: E, A4 2020 MSBC occupant
Minneapolis permit records name B and D Plumbing Heating and A/C Inc, Rochon Corporation and GR Mechanical Plumbing & Heating as the contractors on this project, among 4 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
6 permits issued Jun 23 – Jun 9, newest first.
| Issued | Permit | Contractor |
|---|
In Minneapolis, biggest first.
| Value |
|---|
#BLDG1183222 Mechanical · ComMFDNR Gas piping to 4 rooftop units and condensate piping for one mini split. Status: Issued | GR Mechanical Plumbing & Heating | $24K | |
#BLDG1165493 Mechanical · ComMFDNR BLDG1165493 New HVAC systems, not to include gas piping work, for Hope Academy. Energy code path is prescriptive. 4 RTU with duct systems, 2-ERU's with ducting, 1 electric hallway heater, 3 exhaust systems and 1 FCU Status: Issued | Allan Mechanical Corp | $462K | |
#BLDG1162114 Plumbing · ComMaj Scope includes storm piping and bathrooms for a building addition. All plumbing shall be installed in accordance with the 2020 Minnesota State Plumbing Code (MSPC), Chapter 4714. All pipe, pipe fittings, traps, fixtures, material, and devices used Status: Issued | B and D Plumbing Heating and A/C Inc | — | |
#BLDG1133757 Plumbing · ComMaj Plumbing for addition and remodeling for a school building. All plumbing shall be installed in accordance with the 2020 Minnesota State Plumbing Code (MSPC), Chapter 4714. All pipe, pipe fittings, traps, fixtures, material, and devices used in the Status: Closed | B and D Plumbing Heating and A/C Inc | — | |
#BLDG1114995 Commercial · Addition 2ND STORY GYM ADDITION. BUILDING D. 2ND FLOOR IS 55,050 SF. (JJL) certificate of occupancy required yes no special inspections required yes AMERICAN ENGINEERING TESTING const type: IB occupancy: E, A4 2020 MSBC occupant Status: Closed | Rochon Corporation | $5.1M | |
#BLDG1115174 Commercial · Addition STORM SHELTER ON LOWER LEVEL. LOCATED IN BUILDING B. (JJL) ***********************REVISION AFTER ISSUANCE. 10/14/25 - ADDING CMU TO AVOID FLUE RELOCATION. (JJL) certificate of occupancy required yes no special inspections required yes AMERICA Status: Closed | Rochon Corporation | $506K |