Get ProEvery project in every city · from $79/mo
Get Procommercial project · Portland, OR
Commercial General Building, Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted October 30, 2024, with 75 permits through October 13, 2026, declaring $5,799,105 of work.
PDOX PS: DEMO ROOFTOP OF PENTHOUSE AND ROOF FRAMING INFILL TO INSTALL ROOFTOP MECHANICAL EQUIPMENT AND ACCOMPANYING STRUCTURAL SUPPORT. W 25-062044-MT
Portland’s permit records for this address don’t name a contractor; the permits list the scope, value and dates below.
75 permits issued Oct 30 – Oct 13, newest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
| applied Sep 25 | #2026-071375-000-00-MT Mechanical Permit · Addition/Alteration/Replace (MT) SINGLEPDF - INSTALL (1) NEW HEAT EXCHANGER FOR EXISTING CHILLER TO PROVIDE BACKUP COOLING IN THE EVENT OF CHILLER FAILURE. INSTALL PIPING AS SHOWN ON PLANS. INSTALL PIPING TO (2) NEW OWNER PROVIDED COMPUTER ROOM AIR HANDLING (CRAH) |
Status: Issued
| Not published |
| — |
| applied Aug 14 | #2026-060756-000-00-ET Electrical Permit · Addition/Alteration/Replacement AC AND CCTV CABLING Status: Issued | Not published | — |
| applied Jun 30 | #2026-048123-000-00-MT Mechanical Permit · Addition/Alteration/Replace (MT) SINGLEPDF - MOVED SOME SEGMENTS AWAY FROM STAIRCASE PER ASBUILD AND NEW REVISION PAGES; TRANSFER GRILL SIZES HAVE BEEN CHANGED Status: Final | Not published | — |
| applied Jul 7 | #2026-050097-000-00-ET Electrical Permit · Addition/Alteration/Replacement 25297 Pittock Block Building - 7th Floor - DCI TI Project - Low Voltage Alteration - Relocate four (4) Thermostats. Status: Final | Not published | — |
| applied Dec 11 | #2025-097525-000-00-FS Fire Systems Permit · Alteration ALARM - FIRE ALARM INSTALLATION FOR NEW TENANT Status: Final | Not published | — |
| applied Mar 4 | #2022-133084-DFS-41-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR T-200 STRUCTURAL PARTIAL WALL BRACING Status: Final | Not published | $3.5K |
| applied Apr 27 | #2026-030136-000-00-ET Electrical Permit · Addition/Alteration/Replacement Data Cabling Status: Final | Not published | — |
| applied Feb 12 | #2022-133084-DFS-16-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT AT MEZZANINE Status: Final | Not published | — |
| applied Mar 26 | #2025-075396-REV-01-CO Commercial Building Permit · Alteration PDOX PS: NO VALUE ADDED REVISION TO ADD STRUCTURAL DETAILS FOR SLIDING DOOR HEAD PER INSPECTOR REQUEST. Status: Final | Not published | — |
| applied Mar 12 | #2022-133084-DFS-42-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR INSTALLING SEISMIC BRACING FOR BASEMENT ONLY CHILLER CONDUITS Status: Under Inspection | Not published | — |
| applied Feb 20 | #2022-133084-DFS-39-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR LEVEL 4 CORRIDOR ELECTRICAL CONDUIT RACK SEISMIC BRACING Status: Final | Not published | — |
| applied Feb 24 | #2022-133084-DFS-40-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR SEISMIC INSTALLATION FOR VEGA PATHWAYS CONDUIT AND LADDER RACK ATTACHING TO WALL AND CEILING Status: Final | Not published | — |
| applied Jun 24 | #2022-133084-DFS-26-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR ANCHORAGE FOR FLOOR MOUNTED EQUIPMENT Status: Final | Not published | — |
| applied Mar 13 | #2022-133084-DFS-23-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR NORTH LIGHTWELL RACK DELEGATED DESIGN Status: Final | Not published | — |
| applied Feb 23 | #2025-038949-DFS-02-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR PIPE SUPPORT RACK ON ROOF Status: Final | Not published | — |
| applied Oct 21 | #2025-085458-000-00-FS Fire Systems Permit · Alteration SPRINKLER - INSTALL A PRE-ACTION SYSTEM PER NFPA 13 Status: Final | Not published | — |
| applied Nov 11 | #2022-133084-DFS-34-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR ANCHORING OF GLYCOL MAKE UP UNIT ON THE 8TH FLOOR Status: Final | Not published | — |
| applied Feb 4 | #2022-133084-DFS-38-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR INSTLALLING OF SEISMIC BRACING T200 SUPERSTRUCTURE-CONDUITS AND BUSWAY Status: Final | Not published | — |
| applied Oct 6 | #2025-079833-000-00-CO Commercial Building Permit · Alteration SINGLE PDF - TENANT IMPROVEMENT INVOLVING INTERIOR CONSTRUCTION ON THE SOUTH SIDE OF LEVEL 5, INCLUDING THE INSTALLATION OF NEW INTERIOR FURRING WALLS AND FINISHES. Status: Final | Not published | $483K |
| applied Jan 7 | #2026-000652-000-00-FS Fire Systems Permit · Alteration SPRINKLER - ADD SPRINKLERS TO UNPROTECTED SPACE TO BRING UNIT UP TO CODE Status: Final | Not published | — |
| applied Feb 13 | #2026-011354-000-00-ET Electrical Permit · Addition/Alteration/Replacement 741219 - Replace like for like 3000A Main Switch O.T for inspection STAND ALONE PERMIT Status: Final | Not published | — |
| applied Feb 6 | #2026-009352-000-00-ET Electrical Permit · Addition/Alteration/Replacement Add lights receptacles to new office for DCI Status: Final | Not published | — |
| applied Oct 15 | #2025-075396-000-00-CO Commercial Building Permit · Alteration PDOX PS: INTERIOR TI FOR NEW TENANT ON LEVEL 7. INCLUDES NON-LOAD BEARING WALLS, OFICE SPACES, KITCHEN, AND STORAGE. Status: Final | Not published | $552K |
| applied Dec 22 | #2022-133084-DFS-37-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR INSTLALLING LIGHTWELL CONDUIT RISER SUPPORTS Status: Final | Not published | — |
| applied Dec 30 | #2022-107630-REV-01-CO Commercial Building Permit · Alteration SINGLE PDF - NON-ADDED VALUE REVISION - UPDATE PLANS TO MATCH SITE CONDITIONS, LOCATION FOR USAGE OF FRP, AND INCLUDE FRP DETAILS AND REMOVE DFS FOR FRP Status: Final | Not published | — |
| applied Nov 4 | #2025-038949-DFS-01-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR STEEL SHIP LADDER Status: Final | Not published | — |
| applied Sep 25 | #2022-133084-REV-03-CO Commercial Building Permit · Alteration PDOX PS- REVISION TO STRUCTURAL DETAILS TO ACCOUNT FOR EXISTING CONDITIONS. Status: Final | Not published | — |
| applied Nov 6 | #2022-133084-DFS-33-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR SEISMIC BRACING FOR CABLE TRAY SUPPORTS, EXCLUDING STRUCTURAL STEEL Status: Final | Not published | — |
| applied Nov 26 | #2022-133084-DFS-36-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR 5TH FLOOR OH CONVEYANCE Status: Final | Not published | — |
| applied Nov 25 | #2022-133084-DFS-35-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR 4TH FLOOR OH CONVEYANCE Status: Final | Not published | — |
| applied Dec 1 | #2025-096765-000-00-ET Electrical Permit · Addition/Alteration/Replacement 741656 - Install parallel 4" EMT fiber conduits on 6th floor from Cage 601.C42 to 601.C15, totaling 90 lineal feet each. No power or low voltage in pathway; fiber/light only. STAND ALONE. Status: Final | Not published | — |
| applied Jul 29 | #2025-061023-000-00-FS Fire Systems Permit · Alteration ALARM - INSTALL SMOKE DETECTION NOTIFICATION IN PREACTION PANEL MONITORING FOR FUTURE TELECOM SPACE (rev description: relocated devices to wall to account for data racks) Status: Final | Not published | — |
| applied Jun 24 | #2022-133084-DFS-28-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR MECHANICAL HANGERS AND SUPPORTS Status: Final | Not published | — |
| applied Sep 26 | #2025-078915-000-00-MT Mechanical Permit · Addition/Alteration/Replace (MT) SINGLEPDF - INSTALLATION OF NEW MECHANICAL SYSTEM FOR LEVEL 5 Status: Final | Not published | — |
| applied Oct 16 | #2025-084507-000-00-MT Mechanical Permit · Addition/Alteration/Replace (MT) SINGLEPDF - DEMOLISH EXISTING DUCTWORK; PROVIDE NEW DISTRIBUTION DUCTWORK AND GRDS; PROVIDE (3) NEW FIRE DAMPERS: PROVIDE (1) CEILING MOUNTED EXHAUST FAN; RELOCATE (4) EXISTING THERMOSTATS Status: Final | Not published | — |
| applied Sep 12 | #2022-133084-DFS-31-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR SEISMIC ANCHORING OF (40) 400A RPP's and MECH A2 and MECH B2 Status: Final | Not published | — |
| applied Aug 4 | #2025-062044-000-00-MT Mechanical Permit · Addition/Alteration/Replace (MT) PDOX PS: INSTALL NEW CHILLER AND ASSOCIATED DUCTWORK FOR PENTHOUSE. W 25-038949-CO Status: Final | Not published | — |
| applied Aug 6 | #2025-038949-000-00-CO Commercial Building Permit · Alteration PDOX PS: DEMO ROOFTOP OF PENTHOUSE AND ROOF FRAMING INFILL TO INSTALL ROOFTOP MECHANICAL EQUIPMENT AND ACCOMPANYING STRUCTURAL SUPPORT. W 25-062044-MT Status: Final | Not published | $3.5M |
| applied Oct 30 | #2025-088926-000-00-ET Electrical Permit · Addition/Alteration/Replacement 25297 Pittock Block Building - 7thFloor - DCI TI Project - Low Voltage Alteration: Relocate four (4) thermostats. Status: Final | Not published | — |
| applied Feb 12 | #2022-133084-DFS-18-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR FLANGE SUPPORT ANCHORAGE Status: Final | Not published | — |
| applied Oct 15 | #2025-084322-000-00-ET Electrical Permit · Addition/Alteration/Replacement New installation of HVAC Controls in basement, 1st floor, 4th floor & penthouse. Status: Final | Not published | — |
| applied Oct 13 | #2025-083440-000-00-ET Electrical Permit · Addition/Alteration/Replacement 741219 Addition to Phase 1 ¿ installation of lighting, receptacles, fire alarm, and security. STAND ALONE PERMIT. Status: Final | Not published | — |
| applied Oct 2 | #2025-080401-000-00-PT Plumbing Permit · Addition/Alteration/Replacement Scope of Work: Provide labor and material for the following: -Install (1) sewage ejector pump under kitchen sink and route overhead to sewer stack connection. -Install (1) kitchen sink -Install (1) ice maker box for fridge and dishwasher Status: Final | Not published | — |
| applied Sep 12 | #2022-133084-DFS-32-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR INSTALLATION OF (16) ATS PANEL FRAME ANCHORAGE Status: Final | Not published | — |
| applied Aug 7 | #2022-133084-DFS-30-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR GENERATOR ROOM STAIRS Status: Final | Not published | — |
| applied May 21 | #2022-133084-REV-02-CO Commercial Building Permit · Alteration SINGLE PDF - REVISION TO DFS FOR STRUCTURAL FRP REINFORCING AND SHOTCRETE AT GENERATOR ROOM COLUMNS Status: Final | Not published | — |
| applied Jul 24 | #2025-058983-000-00-ET Electrical Permit · Addition/Alteration/Replacement PDOX 741219 - ADDITION TO PHASE 1-(40) 400A RPPS, (2) 600A PANELS, BRANCH CIRCUITS, AND SECURITY SYSTEMS. STAND ALONE PERMIT Status: Final | Not published | — |
| applied May 16 | #2022-133084-DFS-25-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR TRANSFORMER VAULT STAIRS Status: Final | Not published | — |
| applied Feb 19 | #2022-133084-DFS-19-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR 8TH FLOOR GENERATOR PLATFORM LADDER Status: Final | Not published | — |
| applied Jul 17 | #2025-057054-000-00-ET Electrical Permit · Addition/Alteration/Replacement PDOX ADDITION TO PHASE 1- (2) 800A FEEDERS FOR COOLING TOWER, (2) 600A PANELS, BRANCH CIRCUITS, CONTROL CIRCUITS AND FIRE ALARM. STAND ALONE PERMIT. 741219 Status: Final | Not published | — |
| applied Feb 12 | #2022-133084-DFS-17-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR HANGERS, SUPPORTS, SEISMIC ANCHORAGE AT FIRST FLOOR Status: Final | Not published | — |
| applied Jul 23 | #2025-056323-000-00-FS Fire Systems Permit · New HAZARDOUS/TANK - INSTALL (2) 275-GALLON DAY TANKS TO SERVICE STAND-BY POWER GENERATORS. AN EXISTING 4000-GALLON TANK WILL SUPPLY FUEL OIL TO THESE TANKS VIA NEW DOUBLE WALLED CARBON STEEL PIPING. Status: Final | Not published | — |
| applied Jun 24 | #2022-133084-DFS-29-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR FUEL OIL PIPING SUPPORT Status: Final | Not published | — |
| applied Jun 24 | #2022-133084-DFS-27-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR NORTH AND WEST ROOF MECHANICAL SUPPORT RACK Status: Final | Not published | — |
| applied Jul 8 | #2025-053906-000-00-ET Electrical Permit · Addition/Alteration/Replacement Install 3PH-30A Circuit to humidifier in 4th floor west mechanical room. ATTACHED TO MAIN ELECTRICAL PERMIT # 23-090321-000-00-ET IVR#4975589 Status: Final | Not published | — |
| applied Jul 8 | #2025-053903-000-00-ET Electrical Permit · Addition/Alteration/Replacement 741219 - Install (5) 120V circuits for Kurita water treatment on 8th floor. STANDALONE PERMIT Status: Final | Not published | — |
| applied Apr 11 | #2025-027575-000-00-CO Commercial Building Permit · Alteration SINGLE PDF: TI TO DEMO INTERIOR WALLS AND FINISHES FOR FUTURE TENANT. Status: Final | Not published | $300K |
| applied Feb 7 | #2022-133084-DFS-15-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR 4TH FLOOR HANGERS, SUPPORTS FOR HVAC PIPING, EQUIPMENT AND CONDUIT RACK SUPPORTS, (1) SUPPORT BEING INSTALLED ON MECHANICAL STEEL SUPPORT BEAM. Status: Final | Not published | — |
| applied Jan 28 | #2022-133084-DFS-14-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR DISTRIBUTED UTILITIES SUPPORT OUTSIDE T-200 Status: Final | Not published | — |
| applied Jan 9 | #2022-133084-DFS-13-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR (2) TRANSFORMERS MOUNT OVERHEAD IN THE T-200 SPACE Status: Final | Not published | — |
| applied Mar 25 | #2022-133084-DFS-24-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR GENERATOR ANCHORAGE Status: Final | Not published | $15.4K |
| applied Mar 4 | #2022-133084-DFS-21-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR LIGHTWELL CONDUIT SUPPORTS: INSTALLING HANGERS AND SUPPORTS FOR ELECTRICAL CONDUIT. Status: Final | Not published | — |
| applied Apr 1 | #2025-025206-000-00-PT Plumbing Permit · Addition/Alteration/Replacement Replace existing water piping and RPBP with new piping and valves. Install new floor sink, trap primer, and associated piping. Status: Final | Not published | — |
| applied Mar 11 | #2022-133084-DFS-22-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR ROOFTOP CONDUIT SUPPORTS Status: Final | Not published | — |
| applied Feb 25 | #2022-133084-DFS-20-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR STEEL INSTALLATION OF ROOM 118 STEEL SUPER STRUCTURE Status: Final | Not published | — |
| applied Sep 27 | #2022-133084-DFS-07-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR STRUCTURAL FRP REINFORCING AND SHOTCRETE AT GENERATOR ROOM COLUMNS Status: Final | Not published | — |
| applied Nov 1 | #2022-133084-REV-01-CO Commercial Building Permit · Alteration SINGLE PDF: VALUE ADDED REVISION FOR STRUCTURAL REPAIR OF EXISTING COLUMNS AFTER THE EXISTING CONDITION WAS EXPOSED DURING CONSTRUCTION. Status: Final | Not published | — |
| applied Oct 17 | #2022-133084-DFS-12-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR GENERATOR ROOM GRATING Status: Final | Not published | — |
| applied Oct 7 | #2022-133084-DFS-08-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR ATTACHMENT OF EQUIPMENT - MT HANGERS & SUPPORTS AND SEISMIC ANCHORAGE Status: Final | Not published | — |
| applied Oct 10 | #2023-090321-000-00-ET Electrical Permit · New Construction NEW DATA CENTER; (2) 4000A SERVICES (2) 3000KW GENERATORS, (4) UPS LINEUPS Status: Final | Not published | — |
| applied Jan 10 | #2025-002582-000-00-ET Electrical Permit · Addition/Alteration/Replacement 741470 Pittock Trane VFDs Replace (3) VFDs for mechanical equipment. No plan review and not under existing construction permit. Status: Final | Not published | — |
| applied Aug 1 | #2024-066277-000-00-CO Commercial Building Permit · Alteration SINGLE PDF - GROUT COLUMN GROUND IMPROVEMENT TO INCREASE BEARING CAPACITY AND REDUCE SETTLEMENT POTENTIAL IN SW CORNER OF BUILDING AND ADD NEW WATERPROOF WATER METER VAULT IN BASEMENT.. Status: Final | Not published | $945K |
| applied Oct 7 | #2022-133084-DFS-10-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR CHILLER, REMOTE RADIATOR, PDU FEEDERS, BUSWAY AND RISER SUPPORTS Status: Final | Not published | — |
| applied Oct 30 | #2024-093470-000-00-ET Electrical Permit · Addition/Alteration/Replacement Adding (1) 200A 120/208 panel, (6) 120 circuits, (600) lineal feet of heat trace and associated equipment on rooftop. Status: Final | Not published | — |
| applied Oct 10 | #2022-133084-DFS-11-CO Commercial Building Permit · Alteration SINGLE PDF - DFS FOR WALL MOUNT CABLE TRAY SUPPORT Status: Final | Not published | — |