Get ProEvery project in every city · from $79/mo
Get Procommercial project · Portland, OR
Commercial General Building, Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted February 26, 2025, with 7 permits through October 27, 2026, declaring $200,000 of work.
SINGLE PDF: TI TO CONVERT EXISTING RESTAURANT TO INDOOR MULTI-FOOD CART SPACE, DOUBLE B OCCUPANCY PER BOD 19-05. REMOVE INTERIOR WALLS, DOORS, ASSOCIATED UTILITIES AND PLUMBING FIXTURES. PROPOSED SPACE INCLUDES CART SPACES, BAR, SEATING AREA, ACCESSIBLE RESTROOM, OFFICE AND UTILITY ROOM. NEW GARAGE DOOR AND EXIT DOOR AT BACK. REMOVE PARKING SPACES (3) AND INSTALL NEW TRASH ENCLOSURE ON PARKING LOT. MECHANICAL, ELECTRICAL, AND PLUMBING PERMITS REQUIRED.
Portland’s permit records for this address don’t name a contractor; the permits list the scope, value and dates below.
7 permits issued Feb 26 – Oct 27, newest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
| applied Sep 28 |
#2026-018398-REV-01-MT Mechanical Permit · Addition/Alteration/Replace (MT) ENP-2; SINGLEPDF - REVISION TO REMOVE EXHAUST FANS FOR FOOD CART SPACES #1 AND #3. EXHAUST FAN PROPOSED IN FOOD CART BAY #2 ONLY. NO CHANGES TO ANY PLAN SPECIFICATIONS OTHER THAN INSTALLATION LOCATIONS. Status: Issued |
| Not published |
| — |
| applied Aug 13 | #2026-059597-000-00-FS Fire Systems Permit · New FIXED SYSTEM - INSTALL A FIXED FIRE SUPPRESSION SYSTEM IN A TYPE I HOOD IN A FOOD TRUCK KITCHEN INSIDE A BUILDING Status: Final | Not published | — |
| applied Mar 12 | #2026-018398-000-00-MT Mechanical Permit · Addition/Alteration/Replace (MT) ENP2- SINGLEPDF - INSTALL (2) MULTI-PORT MINI SPLITS WITH (2) WALL HEADS EACH, VENTING EXISTING BATHROOM FANS OUT THE ROOF, INSTALLING A MAKE UP AIR UNIT WITH HEAT AND EVAPORATOR, INSTALLING (X3) EXHAUST FANS FOR FOOD CARTS VENTED TO THE ROOF Status: Under Inspection | Not published | — |
| applied Apr 13 | #2026-026406-000-00-MT Mechanical Permit · Addition/Alteration/Replace (MT) SINGLEPDF - INSTALL GAS PIPE FOR 3 CARTS Status: Final | Not published | — |
| applied Dec 22 | #2025-102096-000-00-ET Electrical Permit · Addition/Alteration/Replacement New 225 Amp Service with interior feeder and panel. Grounding and Bonding. New circuits for three 50 amp food truck stations, mini split, hood fans, general lighting and outlets for bar and restroom areas, approximately 14 circuits. Resuming work from old permit #24-063817. IVR#506671 Status: Final | Not published | — |
| applied May 23 | #2025-040872-000-00-PT Plumbing Permit · Addition/Alteration/Replacement Plumb for carts and bar Status: Final | Not published | — |
| applied Aug 20 | #2024-063817-000-00-CO Commercial Building Permit · Alteration SINGLE PDF: TI TO CONVERT EXISTING RESTAURANT TO INDOOR MULTI-FOOD CART SPACE, DOUBLE B OCCUPANCY PER BOD 19-05. REMOVE INTERIOR WALLS, DOORS, ASSOCIATED UTILITIES AND PLUMBING FIXTURES. PROPOSED SPACE INCLUDES CART SPACES, BAR, SEATING AREA, ACCESSIBLE RESTROOM, OFFICE AND UTILITY ROOM. NEW… Status: Under Inspection | Not published | $200K |