Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted September 5, 2025, with 4 permits through October 14, 2025. Contractor on record: Houn Far LLC.
Get new commercial permits near 19107 or Philadelphia, free weekly email
1. Install a new 2500A 480V/3PH 4W switchboard, a new 300KW Diesel generator with (2) 480V ATS, (5) 480V 3PH 4W panels, (2) 800A 100FT Busduct through basement to 10th floor and (52) 208V panels for the new hotel. All work is to be completed according to approved drawings, 2018 IBC and 2017 NEC, 2016 NFPA 110 2. Install all new lighting fixtures, receptacles, equipment, kitchen appliances for the new hotel. All work is to be completed according to approved drawings, 2018 IBC and 2017 NEC 3. Install all new fire alarm & evacuation system with new conduits, cables, strobes, speakers, fire…
Philadelphia permit records name Houn Far LLC and Harring Fire Protection, LLC as the contractors on this project.
The property owner is included with Pro.
4 permits issued Sep 5 – Oct 14, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#EP-2025-006949 Electrical Permit · Addition and/or Alteration 1. Install a new 2500A 480V/3PH 4W switchboard, a new 300KW Diesel generator with (2) 480V ATS, (5) 480V 3PH 4W panels, (2) 800A 100FT Busduct through basement to 10th floor and (52) 208V panels for the new hotel. All work is to be completed according to approved drawings, 2018 IBC and 2017 NEC,… Status: Issued | Houn Far LLC | — | |
#PP-2025-009271 Plumbing Permit · New Construction or Additions Plumbing per plans. Status: Issued | Houn Far LLC | — | |
#MP-2025-003822 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO… Status: Issued | Houn Far LLC | — | |
#FP-2025-001795 Fire Suppression Permit · New Construction INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 6" MAIN FIRE SERVICE LINE WITH A 6" AMES COLT 200 BACKFLOW PREVENTION ASSEMBLY, UL LISTED AURORA 4-383-10B FIRE PUMP COMPLYING WITH NFPA 20 AND TWO (2) STANDPIPE RISERS COMPLYING WITH NFPA 14 AS PER… Status: Issued | Harring Fire Protection, LLC | — |