Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted March 6, 2025, with 5 permits through May 7, 2025. Contractor on record: Altin Xhixho.
Install 400A incoming service 120/240V -125A each residential unit -125A service for the house panel -LED disc lights throughout -Decora switches and outlets -Builders grade bath fans -Hardwired smoke alarms -All emergency lighting -New fire alarm installation. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.
Philadelphia permit records name Altin Xhixho, Andrius Ratkevicius Inc and Thomas Uhl as the contractors on this project, among 5 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
5 permits issued Mar 6 – May 7, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#EP-2025-002730 Electrical Permit · New Construction Install 400A incoming service 120/240V -125A each residential unit -125A service for the house panel -LED disc lights throughout -Decora switches and outlets -Builders grade bath fans -Hardwired smoke alarms -All emergency lighting -New fire alarm installation. ALL WORK IS TO BE DONE ACCORDING TO… Status: Completed | Altin Xhixho | — | |
#MP-2025-001130 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, BATHROOM AND CLOTHES DRYER EXHAUSTS, AND ASSOCIATED DUCTWORK THROUGHOUT A THREE-FAMILY DWELLING. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2022-005679 FOR… Status: Completed | Andrius Ratkevicius Inc | — | |
#PP-2025-004154 Plumbing Permit · New Construction or Additions installing 1 1/2" water service, 6" curb trap, 5" main drain & 4" fresh air inlet 1 1/2" Backflow Preventer (RP) Watts LF009M2QT Status: Completed | Thomas Uhl | — | |
#FP-2025-000371 Fire Suppression Permit · New Construction FOR THE INSTALLATION OF A NFPA 13R SYSTEM FOR A MULTI-FAMILY DWELLING SERVICED BY A TWO (2) INCH FIRE SERVICE LINE WITH A 2-INCH WILKINS 950XLT2 BACKFLOW PREVENTER AND AUTOMATIC FIRE SUPPRESSION SYSTEM. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. IF FIELD… Status: Completed | Michael J Mccullough jr | — | |
#PP-2025-002229 Plumbing Permit · New Construction or Additions NEW CONSTRUCTION OF ATTACHED TRIPLEX. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR 44 FIXTURES FROM ROUGH TO FINISH. ALL WORK PERFORMED IN COMPLIANCE WITH 2018 PPC AND APPROVED PLANS. Status: Completed | Ok Plumbing LLC | — |
In Philadelphia, biggest first.