Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted January 29, 2025, with 6 permits through April 29, 2025. Contractor on record: Anmar Electrical Contractor Inc.
Get new commercial permits near 19104 or Philadelphia, free weekly email
FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. **ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.**
Philadelphia permit records name Anmar Electrical Contractor Inc, DWD Mechanical Contractor Inc and Bluestone Communications Inc as the contractors on this project, among 5 contractors in all.
The property owner is included with Pro.
6 permits issued Jan 29 – Apr 29, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#MP-2025-000485 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. **ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.**… Status: Completed | DWD Mechanical Contractor Inc | — | |
#EP-2025-002945 Electrical Permit · Addition and/or Alteration Bluestone Communications, Inc. (BCI) has proposed a Communications Cabling System in accordance with the specifications issued. BCI will provide the necessary labor and material to complete the following tasks: HORIZONTAL CABLING: Cabling will be Berk-Tek Category 6A plenum rated 4-pair. • Provide… Status: Completed | Bluestone Communications Inc | — | |
#EP-2025-001364 Electrical Permit · Addition and/or Alteration Provide new fire alarm devices and wiring on floors 13 and 14 and tie-in to existing building fire alarm system as per 2016 NFPA 72. Status: Completed | Anmar Electrical Contractor Inc | — | |
#PP-2025-001107 Plumbing Permit · Alterations INTERIOR ALTERATIONS TO OFFICE SPACES. INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR NEW AND EXISTING FIXTURES. 74 FIXTURES TO BE INSTALLED. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH 2018 PPC AND APPROVED PLANS. Status: Completed | E. J. Raith Mechanical Inc. | — | |
#EP-2025-000683 Electrical Permit · Addition and/or Alteration Provide new light fixtures, switches, lighting control devices, receptacles, poke-thru(s), cable tray, HVAC power connections, new panels, LV transformers, bus plugs, disconnects, conduit pathways for telecom and temporary power tied to existing panels as per 2017 NEC. All telecom and fire alarm… Status: Completed | Anmar Electrical Contractor Inc | — | |
#FP-2025-000173 Fire Suppression Permit · Addition and/or Alterations EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 403 EXISTING SPRINKLER HEADS, PER NFPA 13 Status: Completed | A & S Sprinkler Co Inc | — |