Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted July 22, 2025, with 5 permits through June 4, 2026. Contractor on record: Steven Birton.
Get new commercial permits near 19132 or Philadelphia, free weekly email
FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13R THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 2" FIRE SERVICE LINE AND 2." DC WILKINS 950 XLT2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.
Philadelphia permit records name Steven Birton, Metropolitan Fire Protection and Bynum Michael S as the contractors on this project, among 4 contractors in all.
The property owner is included with Pro.
5 permits issued Jul 22 – Jun 4, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#FP-2025-001935 Fire Suppression Permit · New Construction FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13R THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 2" FIRE SERVICE LINE AND 2." DC WILKINS 950 XLT2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR… Status: Completed | Metropolitan Fire Protection | — | |
#PP-2025-013068 Plumbing Permit · Alterations INSTALL (2) WATER DISTRIBUTION PIPES. (1) 2" & (1) 1.5" Status: Completed | Steven Birton | — | |
#PP-2025-010427 Plumbing Permit · Alterations INTERIOR ALTERATIONS TO EXISTING 6 DWELLING UNIT BUILDING., INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL WORK TO BE PERFORMED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS. Status: Completed | Steven Birton | — | |
#EP-2025-001379 Electrical Permit · Addition and/or Alteration INSTALL 600 AMP SERVICE, (7) GANG METER BANK, (6) 200 AMP PANELS & FEEDERS, (1) 60 AMP PANEL & FEEDER. INSTALL WIRING THROUGHOUT THE COMMON AREAS, & SIX DWELLING UNITS. INSTALL LIGHTS NORMAL & EMERGENCY, SWITCHES, SENSORS, RECEPTACLES, SMOKE, & CARBON MONOXIDE ALARMS. PROVIDE POWER FOR THE… Status: Completed | Bynum Michael S | — | |
#MP-2025-003211 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, BATHROOM / CLOTHES DRYER / DOMESTIC KITCHEN RANGE EXHAUSTS, AND ASSOCIATED DUCTWORK AND PIPING THROUGHOUT ONE (1) DWELLING UNIT AT THE 3RD FLOOR OF AN EXISTING THREE-STORY MULTI-FAMILY BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE… Status: Completed | Miguel Rodriguez | — |
In Philadelphia, biggest first.