Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted April 9, 2025, with 7 permits through December 18, 2025. Contractor on record: Joseph F Spaeder.
Get new commercial permits near 19104 or Philadelphia, free weekly email
INSTALLATION OF TWO (2) UL LISTED COMMERCIAL KITCHEN EXHAUST HOOD WITH SUPPLY/EXHAUST TIE-IN TO ONE (1) EXHAUST SYSTEM & ALL ASSOCIATED RETURN/EXHAUST DUCTWORK. ***SEPARATE PERMIT SHALL BE REQUIRED FOR INSTALLATION OF AN APPROVED AUTOMATIC FIRE SUPRESSION SYSTEM***
Philadelphia permit records name Joseph F Spaeder, Lor-Mar Mechanical Services LLC and MK Fire Protection & Supply, LLC as the contractors on this project, among 5 contractors in all.
The property owner is included with Pro.
7 permits issued Apr 9 – Dec 18, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#MP-2025-005629 Mechanical / Fuel Gas Permit · Addition and/or Alterations INSTALLATION OF TWO (2) UL LISTED COMMERCIAL KITCHEN EXHAUST HOOD WITH SUPPLY/EXHAUST TIE-IN TO ONE (1) EXHAUST SYSTEM & ALL ASSOCIATED RETURN/EXHAUST DUCTWORK. ***SEPARATE PERMIT SHALL BE REQUIRED FOR INSTALLATION OF AN APPROVED AUTOMATIC FIRE SUPRESSION SYSTEM*** Status: Completed | Joseph F Spaeder | — | |
#FP-2025-002355 Fire Suppression Permit · Addition and/or Alterations EZ KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. FSS # 1 - 6 Gallon Ansul System - Covering 2 hoods FSS #2 - 9 Gallon Ansul System -… Status: Completed | Joseph F Spaeder | — | |
#FP-2025-000987 Fire Suppression Permit · Addition and/or Alterations EXTENSION OF EXISTING SPRINKLER SYSTEM TO THE THIRD THROUGH SIXTH FLOORS OF EXISTING STRUCTURE IN ACCORDANCE WITH NFPA 13 AS PER APPROVED PLANS. NO CHANGE TO EXISTING FIRE MAIN, PUMP AND BACKFLOW ASSEMBLY. Status: Completed | MK Fire Protection & Supply, LLC | — | |
#EP-2025-003446 Electrical Permit · Addition and/or Alteration All electrical work associated with interior alterations for level 3,4,5 & 6 of an existing structure . Install fire alarm for alterations. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72. -SEPARATE ELECTRICAL PERMIT REQ'D FOR THE WORK ON PARTIAL 1ST FL Status: Completed | Madden Electric Associates, Inc | — | |
#PP-2025-004362 Plumbing Permit · Alterations • Furnish and install [14] Electric Water Heaters, [1] Hot Water Return Pump, [1] Grease Interceptor, [4] Hub Drains, [4] Water Closets, [32] Lavatories, [12] Kitchen Sinks, [7] Electric Water Coolers, [1] Shower, [7] Floor Drains, [12] Floor Sinks. • Provide labor and materials to make final… Status: Completed | Lor-Mar Mechanical Services LLC | — | |
#MP-2025-001990 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF FUEL GAS PIPING AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. Status: Completed | Lor-Mar Mechanical Services LLC | — | |
#MP-2025-002010 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTAL4/3 LED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE… Status: Completed | Aerdux Inc | — |