Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted November 6, 2025, with 4 permits through December 9, 2025. Contractor on record: Paramount Electrical.
Install utility supplied pad mount transformer and service conductors, supply and install 2000 amp switchboard, Supply and install feeders to new panelboards, transformers and HVAC equipment. Supply and install branch circuit wiring for new interior and exterior lighting and receptacle outlets , fire pump .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. AMENDMENT: Install fire alarm PER APPROVED DRAWINGS. AMENDMENT 2: TENANT ELECTRICAL FITOUT REMOVED & BATHROOM LOCATION CHANGE ( SEE SHEETS)
Philadelphia permit records name Paramount Electrical, Tandem Associates Inc and Advance Management Corporation as the contractors on this project, among 4 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
4 permits issued Nov 6 – Dec 9, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#EP-2025-010444 Electrical Permit · New Construction Install utility supplied pad mount transformer and service conductors, supply and install 2000 amp switchboard, Supply and install feeders to new panelboards, transformers and HVAC equipment. Supply and install branch circuit wiring for new interior and exterior lighting and receptacle outlets ,… Status: Completed | Paramount Electrical | — | |
#PP-2025-012670 Plumbing Permit · New Construction or Additions Interior plumbing inclusive of bathroom, remote bathroom, interior plumbing fixture schedule and interior plumbing equipment schedule. Other Items Qty 16 Total: Floor Cleanouts QTY 6 Wall Cleanout QTY 1 Vents QTY 3 Grade Cleanout QTY 1 Add backflow for irrigation system **********Removed office… Status: Issued | Tandem Associates Inc | — | |
#FP-2025-002192 Fire Suppression Permit · New Construction FOR INSTALLATION OF 10-INCH FIRE SERVICE LINE, 8-INCH BACKFLOW PREVENTER, FIRE PUMP, AND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13. *AMEND 2/10/26; REVISE PIPING AND SPRINKLER HEADS PER AMENDED CONSTRUCTION DOCUMENTS* Status: Completed | Advance Management Corporation | — | |
#MP-2025-005099 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE… Status: Completed | GEMCO Constructors LLC | — |
In Philadelphia, biggest first.