Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial General Building, Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted April 24, 2025, with 6 permits through April 15, 2026. Contractor on record: Harry Beck.
Install New 600amp Service With 16 Meters, Complete Electrical Fit Out Of 15 Unit Apt Building New Fire Alarm System. According to NFPA 72, 2016 & The Philadelphia Fire Code, 2018. Smoke alarm shall be installed a minimum of 3 feet away from fans and vents.
Philadelphia permit records name Harry Beck, Lithium Construction Group LLC and Thomas Uhl as the contractors on this project, among 5 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
6 permits issued Apr 24 – Apr 15, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#EP-2025-009936 Electrical Permit · New Construction Install New 600amp Service With 16 Meters, Complete Electrical Fit Out Of 15 Unit Apt Building New Fire Alarm System. According to NFPA 72, 2016 & The Philadelphia Fire Code, 2018. Smoke alarm shall be installed a minimum of 3 feet away from fans and vents. Status: Issued | Harry Beck | — | |
#MP-2025-001429 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF HVAC APPLIANCES, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS. *2018 IMC REVIEW* Status: Issued | Lithium Construction Group LLC | — | |
#EP-2026-001701 Electrical Permit · New Construction Install one (1) on-site 100-amp temporary electrical service, including temporary meter socket, service disconnect, grounding electrode system, and distribution as required to provide temporary power during construction. All work shall comply with the 2017 NEC. Status: Completed | Harry Beck | — | |
#PP-2025-006508 Plumbing Permit · New Construction or Additions Installing 90 Fixtures 15 Hot Water Heaters 15 Kitchen Sinks 15 washer Machines 15 Toilets 15 Shower/Tubs 15 Lavs Installing 1 1/2" Water service, 6" Curb Trap, 5" Main Drain, 4" Fresh Air Inlet Status: Issued | Thomas Uhl | — | |
#FP-2025-001841 Fire Suppression Permit · New Construction FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 THROUGHOUT A FOUR (4) STORY MULTI-FAMILY BUILDING TO INCLUDE A TWO (2) INCH FIRE SERVICE LINE AND A TWO-AND-A-HALF (2 1/2) INCH BACKFLOW PREVENTER. CLASS 1 MANUAL WET STANDPIPES TO BE INSTALLED IN INTERIOR EXIT… Status: Issued | Philadelphia Fire Protection Pros | — | |
#SP-2024-001451 Site / Utility Permit · Excavation Site / Utility Permit for CP-2024-005882 EXCAVATION WORK ASSOCIATED WITH NEW CONSTRUCTION OF A MULTI-FAMILY BUILDING AS PER APPROVED PLANS. WORK TO INCLUDE TEMPORARY EXCAVATION SUPPORT SYSTEM. NO BUILDING CONSTRUCTION APPROVED ON THIS PERMIT. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR… Status: Issued | Campos Enterprises LLC | — |
In Philadelphia, biggest first.