Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted June 18, 2026, with 4 permits through August 12, 2026. Contractor on record: New Light Electric Inc.
Get new commercial permits near 19103 or Philadelphia, free weekly email
Install 385 light fixture, 24 exit, 133 switch, 197 receptacle, 25 furniture power, 12 floor receptacle, 12 equipment power, bus switch, 480/277 volt panel, 30 KVA transformer, 208/120 volt panel, meter. Fire Alarm: Install 56 speaker/strobe, 2 smoke detector, 6 relay, 2 NAC panel. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72
Philadelphia permit records name New Light Electric Inc, DWD Mechanical Contractor Inc and A & S Sprinkler Co Inc as the contractors on this project, among 4 contractors in all.
The property owner is included with Pro.
4 permits issued Jun 18 – Aug 12, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#EP-2026-007310 Electrical Permit · Addition and/or Alteration Install 385 light fixture, 24 exit, 133 switch, 197 receptacle, 25 furniture power, 12 floor receptacle, 12 equipment power, bus switch, 480/277 volt panel, 30 KVA transformer, 208/120 volt panel, meter. Fire Alarm: Install 56 speaker/strobe, 2 smoke detector, 6 relay, 2 NAC panel. ALL WORK IS TO… Status: Issued | New Light Electric Inc | — | |
#MP-2026-004197 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE PARTIAL DEMOLITION AND INSTALLATION OF REGISTERS, DIFFUSERS, WITH ASSOCIATED DUCTWORK TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE… Status: Issued | DWD Mechanical Contractor Inc | — | |
#FP-2026-001242 Fire Suppression Permit · Addition and/or Alterations EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (133) SPRINKLER HEADS, PER NFPA 13 Status: Issued | A & S Sprinkler Co Inc | — | |
#PP-2026-008224 Plumbing Permit · Alterations Furnish and install (9) plumbing fixtures, (6) kitchen sinks and (3) hot water heaters, connecting to existing piping. *WITHOUT PIPING* Status: Issued | Tkelly Inc | — |
In Philadelphia, biggest first.