Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted August 27, 2025, with 4 permits through October 10, 2025. Contractor on record: Gutlei Inc.
INTERIOR FIT OUT TO COMMERCIAL SPACE. INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY OR KLISTED FIXTURES CONNECTING TO EXISTING METALLIC PIPING. ALL PIPING UTILIZED IN THE INSTALLATION OF THIS PROJECT SHALL BE METALLIC TO ROOF EXTENSION. ALL FOOD PREP FIXTURES SHALL BE PROVIDED WITH CODE REQUIRED AIR GAPS AND BACKFLOW PREVENTERS. VENTING TO BE DEISGNED AND INSTALLED IN ACCORDANC WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS.
Philadelphia permit records name Gutlei Inc, Altin Xhixho and Sanks Mechanical as the contractors on this project, among 4 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
4 permits issued Aug 27 – Oct 10, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#PP-2025-011210 Plumbing Permit · Alterations INTERIOR FIT OUT TO COMMERCIAL SPACE. INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY OR KLISTED FIXTURES CONNECTING TO EXISTING METALLIC PIPING. ALL PIPING UTILIZED IN THE INSTALLATION OF THIS PROJECT SHALL BE METALLIC TO ROOF EXTENSION. ALL FOOD PREP FIXTURES SHALL BE PROVIDED WITH CODE… Status: Completed | Gutlei Inc | — | |
#EP-2025-008792 Electrical Permit · New Construction Installation of electrical wiring, fixtures and outlets. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. **NO FIRE ALARM ON THIS PERMIT** Status: Completed | Altin Xhixho | — | |
#MP-2025-004412 Mechanical / Fuel Gas Permit · Addition and/or Alterations Installation of (1) heat pump system with 3 ton AC condenser and all required ductwork. All ductwork will be self contained in space per approved plans. Status: Completed | Sanks Mechanical | — | |
#FP-2025-001784 Fire Suppression Permit · Addition and/or Alterations EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. *CP-2024-004255* RELOCATE (8) SPRINKLER HEADS TO ACCOMMODATE NEW TENANT FLOOR PLAN Status: Completed | B M Consulting Services Inc | — |