Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted February 6, 2026, with 6 permits through May 3, 2026. Contractor on record: RTN Fire Alarm & Electrical, LLC.
Get new commercial permits near 19140 or Philadelphia, free weekly email
Install fire alarm system as per drawings and 2016 NFPA 72.
Philadelphia permit records name RTN Fire Alarm & Electrical, LLC, Steven Birton and Justin's Plumbing and Heating LLC as the contractors on this project, among 6 contractors in all.
The property owner is included with Pro.
6 permits issued Feb 6 – May 3, newest first.
| Issued | Permit | Contractor | Value |
|---|
Commercial and multifamily, biggest first.
#EP-2026-003605 Electrical Permit · Addition and/or Alteration Install fire alarm system as per drawings and 2016 NFPA 72. Status: Completed | RTN Fire Alarm & Electrical, LLC | — | |
#PP-2026-001949 Plumbing Permit · New Construction or Additions ALTERATIONS TO CREATE A TRIPLEX. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED… Status: Completed | Steven Birton | — | |
#PP-2026-005136 Plumbing Permit · New Construction or Additions INSTALL/REPAIR/REPLACE SANITARY & STORM CTs, FAIs, MDs & 1" WATER LINE. Status: Completed | Justin's Plumbing and Heating LLC | — | |
#EP-2026-000370 Electrical Permit · Addition and/or Alteration Installation of a 400-amp service, interior wiring of three dwelling units, and common areas. All work per approved plans, NEC 2017 ***NO FIRE ALARM ON THIS PERMIT.*** Status: Completed | marquis henderson | — | |
#FP-2026-000587 Fire Suppression Permit · Addition and/or Alterations INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13R THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE WITH A 2" WILKINS 950XLT2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. Status: Completed | Willis Fire Protection | — | |
#MP-2026-000275 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER… Status: Completed | Isabella & Brothers, inc | — |