Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted July 10, 2025, with 6 permits through February 3, 2026. Contractor on record: B M Consulting Services Inc.
Get new commercial permits near 19121 or Philadelphia, free weekly email
Scope of Work: INSTALL 1600-AMP SERVICE, WIRING THROUGHOUT, INSTALL LIGHT FIXTURES, INSTALL OUTLETS, SWITCHES, SMOKE ALARMS, AND GROUNDING AS PER 2017 NEC. INSTALL FIRE ALARM THROUGHOUT THE BUILDING AS PER 2016 NFPA 72. AMENDMENT: Install 1200 amp single-phase service with grounding as per 2017 NEC.
Philadelphia permit records name B M Consulting Services Inc, Euroquality LLC and Prostar Plumbing LLC as the contractors on this project, among 5 contractors in all.
The property owner is included with Pro.
6 permits issued Jul 10 – Feb 3, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#EP-2025-009643 Electrical Permit · New Construction Scope of Work: INSTALL 1600-AMP SERVICE, WIRING THROUGHOUT, INSTALL LIGHT FIXTURES, INSTALL OUTLETS, SWITCHES, SMOKE ALARMS, AND GROUNDING AS PER 2017 NEC. INSTALL FIRE ALARM THROUGHOUT THE BUILDING AS PER 2016 NFPA 72. AMENDMENT: Install 1200 amp single-phase service with grounding as per 2017 NEC. Status: Amendment Ready For Issue | Euroquality LLC | — | |
#PP-2025-009505 Plumbing Permit · New Construction or Additions INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT AND WATER SUPPLY FOR LISTED FIXTURE ROUGH-IN TO FINISH. 38 WATER CLOSETS, 38 LAVATORY, 38 SHOWER/TUBS, 16 WASHING MACHINE BOXES, 16 KITCHEN SINKS, 16 HOT WATER HEATERS, 2 HOSE BIBBE 1 BACKFLOW DEVICE *******************************Amending plans for… Status: Issued | Prostar Plumbing LLC | — | |
#MP-2025-004900 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE… Status: Issued | A & G Heating And Cooling LLC | — | |
#FP-2025-001965 Fire Suppression Permit · New Construction INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13R THROUGHOUT THE BUILDING TO INCLUDE 4" MAIN FIRE SERVICE LINE WITH A 4" WILKINS 350AST BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. Status: Issued | B M Consulting Services Inc | — | |
#PP-2025-011278 Plumbing Permit · New Construction or Additions Supply and install (1) 6" sanitary sewer - main to building Supply and install (1) 6" storm line - main to building Supply and install (2) 6" curb traps Supply and install (2) 4" fresh air inlets Supply and install new 2" domestic line - Street main to building Supply new 2" water meter to be… Status: Completed | B M Consulting Services Inc | — | |
#SP-2025-000322 Site / Utility Permit · Excavation Site / Utility Permit for CP-2024-006442 Status: Issued | Ar Demolition Inc | — |
In Philadelphia, biggest first.