Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted November 7, 2024, with 7 permits through April 12, 2025. Contractor on record: New City Electric LLC.
Get new commercial permits near 19122 or Philadelphia, free weekly email
INSTALL 600 AMP ELECTRICAL SERVICE AND 7 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 100 AMP SUBPANELS FOR HOUSE, 100 AMP SUBPANEL FOR COMMERCIAL SPACE AND ONE 125 AMP SUBPANEL FOR EACH OF THE 5 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS ACCORDING TO THE 2017 NEC. INSTALL FIRE ALARM SYSTEM ACCORDING TO THE 2016 NFPA 72 AND PER PLANS.
Philadelphia permit records name New City Electric LLC, B M Consulting Services Inc and Ivan Plumbing LLC as the contractors on this project, among 7 contractors in all.
The property owner is included with Pro.
7 permits issued Nov 7 – Apr 12, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#EP-2025-002409 Electrical Permit · New Construction INSTALL 600 AMP ELECTRICAL SERVICE AND 7 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 100 AMP SUBPANELS FOR HOUSE, 100 AMP SUBPANEL FOR COMMERCIAL SPACE AND ONE 125 AMP SUBPANEL FOR EACH OF THE 5 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL… Status: Completed | New City Electric LLC | — | |
#FP-2025-000693 Fire Suppression Permit · Addition and/or Alterations INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 2" FIRE SERVICE LINE AND 2." DC WILKINS 950 XLT2 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. **ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE… Status: Completed | B M Consulting Services Inc | — | |
#PP-2025-001503 Plumbing Permit · New Construction or Additions INSTALL 2 SUMP PUMPS, 2 EJECTOR SUMP PUMPS, 6 SHOWER/TUBS, 8 LAVATORIES, 8 WATER CLOSETS, 1 HAND SINK, 5 WASHING MACHINE BOXES, 7 FLOOR DRAINS, 3 DISHWASHING MACHINES, 5 KITCHEN SINKS, 5 HOT WATER HEATERS AND 1 BACKFLOW PREVENTER ACCORDING TO THE 2018 PPC AND PER PLANS. Status: Completed | Ivan Plumbing LLC | — | |
#MP-2025-001502 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE… Status: Completed | Ymk Construction LLC | — | |
#EP-2024-011731 Electrical Permit · Addition and/or Alteration INSTALL A NEW FIRE ALARM SYSTEM THROUGHOUT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. Status: Completed | B.H. HOLDINGS CORP ( Emergency Response Associates) | — | |
#PP-2024-017425 Plumbing Permit · New Construction or Additions installing 1' water service, 5" curb trap, 5" main drain, 4" fresh air inlet Status: Completed | Thomas Uhl | — | |
#SP-2024-001235 Site / Utility Permit · Excavation Site / Utility Permit for CP-2024-003297 Status: Completed | JC Excavation Services LLC | — |
In Philadelphia, biggest first.