Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted August 5, 2025, with 4 permits through September 9, 2025. Contractor on record: City Lights electric llc.
Get new commercial permits near 19133 or Philadelphia, free weekly email
INSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 125 AMP SUBPANELS FOR HOUSE AND ONE 125 AMP SUBPANEL FOR EACH OF THE 3 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS.
Philadelphia permit records name City Lights electric llc, Elegance Group LLC and Michael J Mccullough jr as the contractors on this project, among 4 contractors in all.
The property owner is included with Pro.
4 permits issued Aug 5 – Sep 9, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|
#EP-2025-006534 Electrical Permit · New Construction INSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 125 AMP SUBPANELS FOR HOUSE AND ONE 125 AMP SUBPANEL FOR EACH OF THE 3 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL… Status: Completed | City Lights electric llc | — | |
#MP-2025-003624 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, BATHROOM AND CLOTHES DRYER EXHAUSTS, AND ASSOCIATED DUCTWORK THROUGHOUT A THREE (3) FAMILY DWELLING. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2021-002981 FOR… Status: Completed | Elegance Group LLC | — | |
#FP-2025-001666 Fire Suppression Permit · New Construction FOR THE INSTALLATION OF A 2-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A 2 INCH WILKINS 950XLT2 BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH NFPA 13R. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. Status: Completed | Michael J Mccullough jr | — | |
#PP-2025-009643 Plumbing Permit · New Construction or Additions Installing 1 1/2" Water service, 6" Curb Trap, 4" Main Drain, 4" Fresh Air Inlet Installing 26 Fixtures 3 HWH 3 KS 3 Washers 6 Toilets 6 Lavs 5 Shower/Tubs Status: Completed | Thomas Uhl | — |