Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted May 22, 2025, with 6 permits through December 8, 2025. Contractor on record: B M Consulting Services Inc.
INSTALL 1200 AMP ELECTRICAL SERVICE AND 16 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 225 AMP SUBPANELS FOR HOUSE, ONE 150 AMP SUBPANEL FOR EACH OF THE 2 DWELLING UNITS. AND ONE 125 AMP SUBPANEL FOR EACH OF THE 13 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE OUTLETS. INSTALL INTERCONNECTED SMOKE AND CO ALARMS. INSTALL FIRE ALARM SYSTEM. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS.
Philadelphia permit records name B M Consulting Services Inc, Eagle Electrical Construction Co Inc and Blerton Islamaj as the contractors on this project, among 5 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
6 permits issued May 22 – Dec 8, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#EP-2025-009867 Electrical Permit · New Construction INSTALL 1200 AMP ELECTRICAL SERVICE AND 16 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 225 AMP SUBPANELS FOR HOUSE, ONE 150 AMP SUBPANEL FOR EACH OF THE 2 DWELLING UNITS. AND ONE 125 AMP SUBPANEL FOR EACH OF THE 13 DWELLING UNITS. INSTALL WIRING, LIGHTING, SWITCHES AND RECEPTACLE… Status: Completed | Eagle Electrical Construction Co Inc | — | |
#MP-2025-004425 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE… Status: Completed | Blerton Islamaj | — | |
#PP-2025-010431 Plumbing Permit · New Construction or Additions NEW CONSTRUCTION OF 15 UNIT APARTMENT BUILDING. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. ALL WORK TO BE PERFORMED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS. Status: Completed | David R Smith | — | |
#PP-2025-009358 Plumbing Permit · New Construction or Additions SUPPLY & INSTALL SANITARY & STORM CTs, FAIs, 6" DRAINs & 2" WDP FROM CURB INTO BUILDING. Status: Completed | B M Consulting Services Inc | — | |
#FP-2025-001276 Fire Suppression Permit · New Construction FOR INSTALLATION OF SPRINKLER SYSTEM PER NFPA 13 WITH 2-INCH FIRE SERVICE LINE AND BFP DEVICE AS PER APPROVED PLANS. Status: Completed | B M Consulting Services Inc | — | |
#SP-2025-000543 Site / Utility Permit · Excavation Site / Utility Permit for CP-2025-000800 AMENDMENT APPROVED AS OF 07/01/2025: TO CHANGE THE EXCAVATION CONTRACTOR; TO REDUCE THE SHEATHING/ SHORING BY REPLACING WITH BENCHING PER APPROVED AMENDED PLANS. Status: Completed | MV Homes, Inc | — |
In Philadelphia, biggest first.