Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted June 16, 2026, with 4 permits through September 29, 2026. Contractor on record: Blue Print Mechanical LLC.
Main Electrical Panel: Install 1 main panel in the basement, distributing power to sub-panels on each floor. Wiring: Run copper wiring from the main panel to sub-panels and outlets. Install dedicated circuits for HVAC units and appliances. Lighting: Install recessed lights, pendant fixtures, and wall-mounted lights as per the lighting schedule. Provide switches for each fixture. Outlets: Install general outlets and dedicated appliance outlets in each unit, with GFCI outlets in kitchens and bathrooms. Grounding: Ensure proper grounding for the entire system as per code. Safety Devices:…
Philadelphia permit records name Blue Print Mechanical LLC, Carlos A Nunez and DC Mechanical II LLC as the contractors on this project.
Phone numbers and the property owner are included with Pro, where the city publishes them.
4 permits issued Jun 16 – Sep 29, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#EP-2026-004121 Electrical Permit · Addition and/or Alteration Main Electrical Panel: Install 1 main panel in the basement, distributing power to sub-panels on each floor. Wiring: Run copper wiring from the main panel to sub-panels and outlets. Install dedicated circuits for HVAC units and appliances. Lighting: Install recessed lights, pendant fixtures, and… Status: Amendment Applicant Revisions | Carlos A Nunez | — | |
#PP-2026-006206 Plumbing Permit · Alterations ALTERATIONS TO FLOORS 2-6 TO CREATE DWELLINGS. ALL WORK BELOW SECOND FLOOR IN COMMERCIAL SPACE IS EXISITNG TO REMAIN. PIPING LOCATED IN COMMERCIAL SPACE SHALL BE METALLIC. ENTING SERVING COMMERICLA SPACE IF INSTALLED I REQUIRED TO BE METALLIC TO ROOF EXTENTION. VENTING TO BE DESIGNED AND INSTALLED… Status: Issued | Blue Print Mechanical LLC | — | |
#FP-2026-000873 Fire Suppression Permit · Addition and/or Alterations EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 18 sprinkler heads Status: Issued | DC Mechanical II LLC | — | |
#MP-2026-002674 Mechanical / Fuel Gas Permit · Addition and/or Alterations FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO… Status: Issued | Blue Print Mechanical LLC | — |