Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted April 8, 2026, with 6 permits through August 31, 2026. Contractor on record: Ascension Projects LLC.
FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.
Philadelphia permit records name Ascension Projects LLC, Callisto Energy Management Corporation and Shegda Construction Corp as the contractors on this project, among 6 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
6 permits issued Apr 8 – Aug 31, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#MP-2026-003763 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE… Status: Issued | Ascension Projects LLC | — | |
#EP-2026-003980 Electrical Permit · New Construction Install 400amp service 4-gang meter socket, 4 breaker panels. Rewire with outlets, lights, fixtures, switches smoke/co alarms, water heater, dryer, range, line to power hvac equipment. Install new fire alarm system .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.… Status: Issued | Callisto Energy Management Corporation | — | |
#PP-2026-006916 Plumbing Permit · New Construction or Additions NEW CONSTRUCTION OF TRIPLEX. INTERIOR INSTALLATION OF DRAINAGE, WASTE, VENT, AND WATER SUPPLY FOR LISTED FIXTURES. VENTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK TO BE INSTALLED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS Status: Issued | Shegda Construction Corp | — | |
#PP-2026-011216 Plumbing Permit · New Construction or Additions Exterior Storm and Sanitary Plumbing for New Construction in accordance with EZ Permit Standard for Plumbing. CTs, FAIs & MDs. - Exterior 1.5" Water Distribution for New Construction in accordance with EZ Permit Standard for Plumbing. Status: Issued | Prostar Plumbing LLC | — | |
#FP-2026-000697 Fire Suppression Permit · New Construction FOR THE INSTALLATION OF A 2-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A 2 INCH WILKINS 950XLT2 BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH NFPA 13R. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/ HYDRAULIC CALCULATIONS. Status: Issued | Willis Fire Protection | — | |
#SP-2026-000363 Site / Utility Permit · Excavation Site / Utility Permit for CP-2026-001245 Status: Issued | L G E Trucking LLC | — |
In Philadelphia, biggest first.