Get ProEvery project in every city · from $79/mo
Get Procommercial project · Philadelphia, PA
Commercial Electrical, Fire Protection, Hvac/Mechanical, Plumbing work permitted May 6, 2026, with 4 permits through July 5, 2026. Contractor on record: Sigma Electric Group Inc.
Install 800 A 120/240 V incoming service Wiring of 9 apartment , 30 space 150A MLO electric panels , All electric appliances Wiring of the common areas with exit and emergency signs required Decora switches and outlets throughout, New fire alarm installation . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72. -NOTED: BOTH DOORS FROM ELECTRICAL RM TO BE EQUIPPED W/ PANIC HARDWARE
Philadelphia permit records name Sigma Electric Group Inc, Air Tight Heating And Cooling and Aqueduct Fire Protection Systems, LLC as the contractors on this project, among 4 contractors in all.
Phone numbers and the property owner are included with Pro, where the city publishes them.
4 permits issued May 6 – Jul 5, newest first.
Commercial and multifamily, biggest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
#EP-2026-004538 Electrical Permit · New Construction Install 800 A 120/240 V incoming service Wiring of 9 apartment , 30 space 150A MLO electric panels , All electric appliances Wiring of the common areas with exit and emergency signs required Decora switches and outlets throughout, New fire alarm installation . ALL WORK IS TO BE DONE ACCORDING TO… Status: Issued | Sigma Electric Group Inc | — | |
#MP-2026-002934 Mechanical / Fuel Gas Permit · New Construction FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, BATHROOM AND CLOTHES DRYER EXHAUSTS, AND ASSOCIATED DUCTWORK AND PIPING THROUGHOUT A NINE (9) DWELLING UNIT MULTI-FAMILY BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER… Status: Issued | Air Tight Heating And Cooling | — | |
#FP-2026-000809 Fire Suppression Permit · New Construction FOR THE INSTALLATION OF FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE WITH 2-INCH WILKINS 950XL3 BACKFLOW PREVENTER AND AUTOMATIC FIRE SUPPRESSION SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS/ CALCULATIONS. IF FIELD CONDITIONS VARY… Status: Issued | Aqueduct Fire Protection Systems, LLC | — | |
#PP-2026-005488 Plumbing Permit · New Construction or Additions Installing 1 1/2" Water Service, 6" Main Drain, 6" Curb Trap, 4" Fresh Air Inlet Installing 72 Fixtures 9 HWH 15 Lavs 15 Toilets 9 KS 9 Washers 15 Shower/tubs Status: Issued | Thomas Uhl | — |
In Philadelphia, biggest first.