Get ProEvery project in every city · from $79/mo
Get Procommercial project · New York City, NY
Commercial General Building, Fire Protection, Hvac/Mechanical, Plumbing work permitted November 27, 2024, with 10 permits through May 22, 2026, declaring $200,000 of work. Contractor on record: Navillus Tile Inc.
M533 : 800 Division Road : New Installation of 2 Electric Boilers and associated equipment and piping.
New York City permit records name Navillus Tile Inc, Eagle 1 Mechanical, Inc and A & F Fire Protection Co as the contractors on this project.
Phone numbers and the property owner are included with Pro, where the city publishes them.
10 permits issued Nov 27 – May 22, newest first.
| Issued | Permit | Contractor | Value |
|---|
Commercial and multifamily, biggest first.
| applied Aug 14 | #M00936068-S7-BE Boiler Equipment · Initial Permit M533 : 800 Division Road : New Installation of 2 Electric Boilers and associated equipment and piping. Status: Permit Issued | Eagle 1 Mechanical, Inc | $200K |
| applied Jul 8 | #M00936068-S5-PL Plumbing · Initial Permit M533 : EXTERIOR PLUMBING for the 5 Story Educational Structure with Entrance along Division Road; Install Connection of 10 Sanitary Sewer, 8 Sanitary Sewer, 8 Storm along Division Road and 8 Sanitary Sewer Connection Along Center Way. Status: Permit Issued | Eagle 1 Mechanical, Inc | — |
| applied Jun 5 | #M00936068-S9-EW-SD Sprinklers · Initial Permit M533 : 800 Division Road , Governor's Island : Installation of Sprinklers and Standpipe for a 5 Story Education Structure. Status: Permit Issued | A & F Fire Protection Co | — |
| applied Jun 5 | #M00936068-S9-EW-SP Sprinklers · Initial Permit M533 : 800 Division Road , Governor's Island : Installation of Sprinklers and Standpipe for a 5 Story Education Structure. Status: Permit Issued | A & F Fire Protection Co | — |
| applied Aug 15 | #M00936068-I1-GC General Construction · Renewal Permit Without Changes HUB Consultation Accepted. Construction of a 5 Story Educational Structure with Roof and Roof Terraces with Entrance along Division Road. The Design of the Secondary Connection shall be phased and should not impact obtaining TCO for the New School. Status: Permit Issued | Navillus Tile Inc | — |
| applied Aug 15 | #M00936068-S4-GC Structural · Renewal Permit Without Changes M533 : GC/ST : Superstructure : Installation of reinforced Concrete Columns, Reinforced Concrete Beams, Slabs, Steel beams, Steel Girders, Joist, Reinforced Concrete Slabs on Metal Decking, Non Bearing Walls, Brace Framing, Structural Framing of Roofs etc Status: Permit Issued | Navillus Tile Inc | — |
| applied Aug 15 | #M00936068-S4-ST General Construction · Initial Permit M533 : GC/ST : Superstructure : Installation of reinforced Concrete Columns, Reinforced Concrete Beams, Slabs, Steel beams, Steel Girders, Joist, Reinforced Concrete Slabs on Metal Decking, Non Bearing Walls, Brace Framing, Structural Framing of Roofs etc Status: Permit Issued | Navillus Tile Inc | — |
| applied Aug 13 | #M00936068-S8-MS Mechanical Systems · Initial Permit M533 : 800 Division Road : Installation of Mechanical Systems including Ventilation, Cooling, heating and Dehumidification System associated units, ductwork, fittings, anchors Status: Permit Issued | Navillus Tile Inc | — |
| applied Aug 14 | #M00936068-S3-FO Foundation · Initial Permit Foundation : Installation of Pile Caps and Pile Caps Mating at Columns, Reinforced Grade Beams, Reinforced Slab Footings, Reinforced Concrete Frame Slab on Grade and on Ground, Reinforced Strap Beams, Reinforced Wall Footings. Status: Permit Issued | Navillus Tile Inc | — |
| applied Aug 14 | #M00936068-S6-PL Plumbing · Initial Permit M533 : Interior and Underground Plumbing for the 5 Story Educational Structure. No GAS Connection. Status: Permit Issued | Eagle 1 Mechanical, Inc | — |
In New York City, biggest first.