Multifamily General Building, Electrical, Plumbing work permitted March 10, 2025, with 6 permits through April 30, 2026, declaring $302,000 of work. Contractor on record: Finnegan Development, Inc.
SPR 2019 CBC: RENOVATION OF EXISTING TWO STORY + BASEMENT EIGHT DWELLING UNIT RESIDENTIAL BUILDING. NEW MECHANICAL, ELECTRICAL AND PLUMBING DISTRIBUTION. OCCUPANCY GROUP R-2. CONSTRUCTION CLASSIFICATION III-A.
Chicago permit records name Finnegan Development, Inc, SFW Contracting and Loyal Howard as the contractors on this project.
Phone numbers and the property owner are included with Pro, where the city publishes them.
6 permits issued Mar 10 – Apr 30, newest first.
| Issued | Permit | Contractor | Value |
|---|
In Chicago, biggest first.
| applied Apr 28 | #B200468190 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LINE VOLTAGE ELECTRICAL WORK. ADD 8 CIRCUITS TO EXISTING 400 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 30 . LIGHTING OUTLETS: 32. SPECIFIC LOCATION: BASEMENT, FIRST ¿OOR, SECOND ¿OOR AND EXTERIOR. Status: Complete | SFW Contracting | $62K |
| applied Jan 23 | #101078653 PERMIT - RENOVATION/ALTERATION REVISION TO PERMIT 101062345 FOR ADDITION OF NEW STRUCTURAL BEAMS AND COLUMNS IN ORDER TO ADDRESS A DISCOVERED CONDITION WHICH BECAME APPARENT DURING DEMOLITION WORK. EXISTING AND PROPOSED USES ARE SAME THAT IS RESIDENTIAL GROUP R-2 Status: Active | Finnegan Development, Inc | $10K |
| applied Mar 26 | #B200463516 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LINE VOLTAGE ELECTRICAL WORK. ADD 8 CIRCUITS TO EXISTING 400 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 30 . LIGHTING OUTLETS: 32. SPECIFIC LOCATION: BASEMENT, FIRST FLOOR, SECOND FLOOR AND EXTERIOR. Status: Complete | SFW Contracting | $30K |
| applied Dec 4 | #B200453183 PERMIT – EXPRESS PERMIT PROGRAM · Administrative Change FOR PERMIT 101063245: REPLACEMENT PLUMBING CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE. Status: Complete | Loyal Howard | — |
| applied Jan 15 | #101063245 PERMIT - RENOVATION/ALTERATION SPR 2019 CBC: RENOVATION OF EXISTING TWO STORY + BASEMENT EIGHT DWELLING UNIT RESIDENTIAL BUILDING. NEW MECHANICAL, ELECTRICAL AND PLUMBING DISTRIBUTION. OCCUPANCY GROUP R-2. CONSTRUCTION CLASSIFICATION III-A. Status: Active | Finnegan Development, Inc | $150K |
| applied Feb 27 | #B200414832 PERMIT – EXPRESS PERMIT PROGRAM · Nonstructural Interior Work NONSTRUCTURAL INTERIOR PREPARATORY DEMOLITION: REMOVAL OF DRYWALL/NON-LOAD BEARING PARTITONS AND MEP. ALL OTHER WORK UNDER APPLICATION/PERMIT # 101063245. LOCATIONS: 8 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1 INTERIOR COMMON AREAS, INTERIOR OF BASEMENT, 1ST, 2ND. Status: Suspended | Finnegan Development, Inc | $50K |