Commercial General Building, Electrical, Elevator, Fire Protection, Sign work permitted October 30, 2024, with 43 permits through October 7, 2026, declaring $25,752,781 of work. Contractor on record: Power Construction Company, LLC.
Get new commercial permits in Chicago, free weekly email
SELF-CERTIFICATION 2019 CBRC: INTERIOR ALTERATION OF EXISTING OFFICE SPACE IN AN EXISTING HIGH RISE OFFICE BUILDING. THE SCOPE OF WORK INCLUDES MINOR DEMOLITION OF TEMPORARY LIGHTING, INSTALLATION OF NEW DRYWALL, GLASS, DOORS, FLOORING, MILLWORK, AND LED LIGHTING. THE WORK ALSO INCLUDES REWORKING THE EXISTING, ELECTRICAL, HVAC, PLUMBING AND FIRE PROTECTION. NO CHANGE TO DEMISING WALLS OR COMMON AREA. EXISTING USE = BUSINESS, PROPOSED USE = BUSINESS
Chicago permit records name Power Construction Company, LLC, Siemens Industry Inc and Anthony Bonilla as the contractors on this project, among 21 contractors in all.
The property owner is included with Pro.
In Chicago, biggest first.
43 permits issued Oct 30 – Oct 7, newest first.
| Issued | Permit | Contractor | Value |
|---|---|---|---|
| applied Oct 6 | #B200512269 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101085909. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 12TH & 14TH FLOOR. Status: Active | Contractor with Pro | — |
| applied Jul 22 | #B200476951 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101080296. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 5TH FLOOR. Status: Active | Barry Lymperopoulos | — |
| applied Jul 20 | #101085909 PERMIT - RENOVATION/ALTERATION SELF-CERT 2019 CBRC: INTERIOR BUILD-OUT OF TENANT OFFICE SPACES ON THE 12TH AND 14TH FLOOR FOR TENANT (HUNTINGTON NATIONAL BANK) AS PER PLANS. WORK TO INCLUDE INTERIOR PARTITIONS, DOORS AND HARDWARE, CEILINGS, LIGHTING, FINISHES, MILLWORK, MECHANICAL, ELECTRICAL, AND PLUMBING. DEMOLITION WORK FOR… Status: Active | Knudsen Construction, Inc. | $3.4M |
| applied Jun 29 | #101085335 PERMIT - RENOVATION/ALTERATION SELF-CERT 2019 CBC: INTERIOR ALTERATIONS TO 11TH FLOOR. SCOPE CONSISTS OF 4 SPEC SUITES (1100, 1125, 1135, & 1150), FULL RESTROOM RENOVATIONS, ONE NEW SINGLE OCCUPANCY TOILET ROOM, A SHARED WELLNESS ROOM, AND ELEVATOR LOBBY AND COMMON AREAS. ALL WORK AS PER PLANS. IA CONSTRUCTION, B-BUSINESS… Status: Active | Power Construction Company, LLC | $4.6M |
| applied Jun 17 | #B200472711 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101080296. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 5TH FLOOR. Status: Active | Siemens Industry Inc | — |
| applied Jun 16 | #B200474923 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL OTHER. SPECIFIC LOCATION: 15TH FLOOR. Status: Active | Gibson Electric Co., Inc. | $100 |
| applied Jun 12 | #B200472620 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101083322. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: YES. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 15TH FLOOR. Status: Active | Convergint Technologies LLC | — |
| applied Jun 15 | #101084126 PERMIT - RENOVATION/ALTERATION SELF-CERT 2019 CBRC: INTERIOR DEMOLITION OF NON-LOAD BEARING PARTITIONS TO EXISTING TENANT (HUNTINGTON NATIONAL BANK) OFFICE SUITE 1450 AS PER PLANS. WORK LIMITED TO REMOVAL OF NON-LOAD BEARING INTERIOR PARTITIONS AND ASSOCIATED MEP SYSTEMS. NO CHANGE IN USE. NO STRUCTURAL WORK. (CONSTRUCTION… Status: Active | Knudsen Construction, Inc. | $195K |
| applied Jun 5 | #B200473352 PERMIT – EXPRESS PERMIT PROGRAM · Administrative Change FOR PERMIT 101083322: REPLACEMENT GENERAL CONTRACTOR. REPLACEMENT ELECTRICAL CONTRACTOR. REPLACEMENT PLUMBING CONTRACTOR. REPLACEMENT OTHER CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE. Status: Complete | Development Solutions, Inc | — |
| applied May 28 | #101083322 PERMIT - RENOVATION/ALTERATION SELF CERT 2019 CBRC INTERIOR ALTERATIONS TO SUITE 1500 FOR MICHAEL BAKER.. WORK INCLUDES MEW PARTITIONS, FINISHES, MILLWORK, MECHANICAL, ELECTRICAL AND PLUMBING, AS PER PLANS. NO STRUCTURAL WORK. NO CHANGE IN USE B-BUSINESS AND CONSTRUCTION TYPE 1A Status: Active | Power Construction Company, LLC | $843K |
| applied May 5 | #B200469345 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL DATA/VIDEO. SPECIFIC LOCATION: 8TH FLOOR. Status: Active | Img Technologies, Inc. | $104K |
| applied Apr 22 | #101081778 PERMIT - RENOVATION/ALTERATION SELF-CERT 2019 CBRC: ALTERATIONS OF EXISTING CONFERENCE CENTER INCLUDING DEMOLITION AND REPLACEMENT OF EXISTING PARTITIONS, LIGHTING, AND FINISHES. INTERIORS WORK ONLY. (OCCUPANCY GROUP A-3 - ASSEMBLY, CONSTRUCTION TYPE 1A) Status: Active | Power Construction Company, LLC | $1.8M |
| applied Apr 15 | #101081955 PERMIT - RENOVATION/ALTERATION SELF CERT 2019 CBRC REHABILITATION OF EXISTING COVERED OUTDOOR DINING PATIO AREA INCLUDING NEW FINISHES LIGHTING FIXTURES AND HEATERS (CON TYPE 1A FS OCC A2 B) Status: Active | Crane Construction Company, L.L.C. | $145K |
| applied Mar 12 | #101080784 PERMIT - RENOVATION/ALTERATION SELF-CERT 2019 CBC: INTERIOR ALTERATIONS TO 5TH FLOOR RESTROOMS AS PER PLANS. IA CONSTRUCTION, B-BUSINESS OCCUPANCY Status: Active | O'malley Construction Company | $270K |
| applied Mar 12 | #101080806 PERMIT - RENOVATION/ALTERATION SELF-CERT 2019 CBC: INTERIOR ALTERATIONS TO 13TH FLOOR RESTROOMS AS PER PLANS. IA CONSTRUCTION, B-BUSINESS OCCUPANCY Status: Active | O'malley Construction Company | $270K |
| applied Mar 2 | #101080296 PERMIT - RENOVATION/ALTERATION SELF-CERTIFICATION 2019 CBRC: INTERIOR ALTERATION OF EXISTING OFFICE SPACE IN AN EXISTING HIGH RISE OFFICE BUILDING. THE SCOPE OF WORK INCLUDES MINOR DEMOLITION OF TEMPORARY LIGHTING, INSTALLATION OF NEW DRYWALL, GLASS, DOORS, FLOORING, MILLWORK, AND LED LIGHTING. THE WORK ALSO INCLUDES REWORKING… Status: Complete | Development Solutions, Inc | $6M |
| applied Jan 15 | #B200455781 PERMIT – EXPRESS PERMIT PROGRAM · Other Work NONSTRUCTURAL INTERIOR REPLACEMENT OF WATER/SMOKE/FIRE DAMAGES TO INCLUDE 3000 SQ FT DRYWALL, PLUMBING FIXTURES AND ASSOCIATED PIPING, ELECTRICAL AND DUCTWORK. REPLACE STUDS AS NEEDED AT 1ST AND 2ND FLOR KITCHING AND DINING ROOMS. COOKING CONNECTIONS TO BE REPLACED AS EXISTING. NO FLOOR PLAN… Status: Active | Crane Construction Company, L.L.C. | $750K |
| applied Oct 23 | #101075760 PERMIT - SIGNS DOUBLE FACE NON ILLUMINATED BLADE SIGN READING "FATBACK THE GREEN BUTCHER" ON THE NORTH ELEVATION | All-Right Sign Inc | $1.5K |
| applied Jul 28 | #B200435187 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101067912. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 4TH FLOOR TENANT. Status: Complete | Siemens Industry Inc | — |
| applied Aug 20 | #B200438625 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101070593. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 1ST FLOOR TENANT. Status: Suspended | Siemens Industry Inc | — |
| applied Aug 14 | #B200437250 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101067912. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 4TH FLOOR. Status: Suspended | Barry Lymperopoulos | — |
| applied Aug 13 | #B200437896 PERMIT – EXPRESS PERMIT PROGRAM · Administrative Change FOR PERMIT 101070593: REPLACEMENT OTHER CONTRACTOR. ADDITIONAL OTHER CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE. Status: Complete | Sherman Mechanical, Inc. | — |
| applied Aug 13 | #B200437900 PERMIT – EXPRESS PERMIT PROGRAM · Administrative Change FOR PERMIT 101070596: REPLACEMENT OTHER CONTRACTOR. ADDITIONAL OTHER CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE. Status: Complete | Sherman Mechanical, Inc. | — |
| applied Jul 14 | #B200433776 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL DATA/VIDEO. SPECIFIC LOCATION: 4TH FLOOR. Status: Complete | KB Advanced Technologies Co. | $380K |
| applied Jun 16 | #101070596 PERMIT - RENOVATION/ALTERATION SELF-CERT PERMIT ** INTERIOR RENOVATION OF EXISTING TENANT BUSINESS SUITE ON FLOOR 1. RENOVATION INCLUDES NEW INTERIOR PARTITIONS, CEILINGS, LIGHTING, KITCHEN EQUIPMENT AND FINISHES AS WELL AS THE REWORKING OF HVAC, ELECTRICAL, PLUMBING, SPRINKLERS AND FIRE ALARM.CURRENT USE: OFFICE -… Status: Active | Power Construction Company, LLC | $90.7K |
| applied Jun 16 | #101070593 PERMIT - RENOVATION/ALTERATION SELF-CERT PERMIT ** INTERIOR RENOVATION OF EXISTING TENANT BUSINESS SUITE ON FLOOR 1. RENOVATIONINCLUDES NEW INTERIOR PARTITIONS, CEILINGS, LIGHTING AND FINISHES AS WELL AS THE REWORKING OF HVAC, ELECTRICAL, PLUMBING, SPRINKLERS AND FIRE ALARM.CURRENT USE: OFFICE - BUSINESSPROPOSED USE: RESTAURANT… Status: Complete | Power Construction Company, LLC | $91.2K |
| applied Jul 9 | #B200433181 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 736 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: 4TH FLOOR. Status: Complete | Lombardi Electric, Inc. | $77.6K |
| applied Jul 2 | #B200432527 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL OTHER. SPECIFIC LOCATION: 4TH FLOOR. Status: Complete | Integrated Control Technologies LLC | $18K |
| applied Jul 2 | #B200432430 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. ALTER EXISTING AUDIO. SPECIFIC LOCATION: 4TH FLOOR. Status: Active | Avi-SPL LLC | $255K |
| applied Jul 2 | #101071268 PERMIT - ELEVATOR EQUIPMENT HOIST CABLE REPLACEMENT ON ONE(1) 4500LB CAPACITY, 26-FLOOR, 700FPM, PASSENGER ELEVATOR(#12), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV003622) | TK Elevator | $7.5K |
| applied May 19 | #B200426327 PERMIT – EXPRESS PERMIT PROGRAM · Nonstructural Interior Work SCOPE: NONSTRUCTURAL INTERIOR ALTERATION TO REMOVE GLASS PARTITION / DOOR, ADD OPENING TO DRYWALL PARTITION, ADD RECEPTACLES FOR NEW TV AND RECEPTION DESK. LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), SUITE 1510. Status: Complete | Wigmore Construction, LLC | $17.1K |
| applied Jun 5 | #B200427618 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101064437. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: NONE (EXEMPT) . SPECIFIC LOCATION: 19TH FLOOR - SUITE 1935. Status: Suspended | Anthony Bonilla | — |
| applied Jun 5 | #B200427595 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101037716. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: NONE (EXEMPT) . SPECIFIC LOCATION: 19TH FLOOR - SUITE 1950. Status: Suspended | Anthony Bonilla | — |
| applied Jun 5 | #B200427612 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101064437. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: NONE (EXEMPT) . SPECIFIC LOCATION: 19TH FLOORS - SUITE 1925. Status: Suspended | Anthony Bonilla | — |
| applied May 2 | #101067912 PERMIT - RENOVATION/ALTERATION SELF CERT 2019 CBRC: INTERIOR ALTERATIONS ON THE 4TH FLOOR, TO EXPAND EXISTING OFFICE TENANT SUITE 400 TO A FULL FLOOR OFFICE TENANT SPACE. NEW PARTITIONS, PLUMBING, VENTILATION AND ELECTRICAL WORK AS PER PLANS. (OCCUPANCY GROUP B; TYPE 1A CONSTRUTION) Status: Complete | Skender Construction LLC | $3.9M |
| applied Apr 18 | #B200421638 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 19TH FLOOR. Status: Suspended | Siemens Industry Inc | — |
| applied Apr 1 | #101067220 PERMIT - RENOVATION/ALTERATION ** SELF CERT PERMIT ** INTERIOR DEMOLITION OF EXISTING TENANTS BUSINESS SUITE ON FLOOR 1. SCOPE INCLUDES DEMOLITION OF EXISTING SPACES. CURRENT USE: BUSINESS. PROPOSED USE: BUSINESS. Status: Suspended | Milburn LLC | $186K |
| applied Feb 28 | #101065662 PERMIT - RENOVATION/ALTERATION SELF-CERT 2019 CBRC: *INTERIOR DEMOLITION ONLY* ON THE 5TH FLOOR OF AN EXISTING HIGH RISE OFFICE BUILDING PER PLANS. NO STRUCTURAL WORK TO BE PERFORMED. (1A CONSTRUCTION, B-BUSINESS OCCUPANCY) Status: Active | Milburn LLC | $205K |
| applied Jan 28 | #B200412346 PERMIT – EXPRESS PERMIT PROGRAM · Electrical Work LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 92 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: 2ND FLOOR. Status: Complete | Lombardi Electric, Inc. | $11.5K |
| applied Jan 22 | #101064437 PERMIT - RENOVATION/ALTERATION SELF CERT 2019 CBRC: INTERIOR RENOVATIONS TO THE 19TH FLOOR TO INCLUDE THE BUILD OUT OF FOUR SPEC SUITE OFFICE SPACES, ELEVATOR LOBBY, AND TENANT CORRIDORS. DEMO, NEW PARTITIONS, MECHANICAL, ELECTRICAL AND PLUMBING AS PER PLANS. B-BUSINESS. 1A CONSTRUCTION Status: Complete | Power Construction Company, LLC | $2.4M |
| applied Nov 6 | #101062005 PERMIT - ELEVATOR EQUIPMENT REPLACE SHEAVE ON PASSENGER CAR 12, SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION. | TK Elevator | $20K |
| applied Nov 1 | #B200403544 PERMIT – EXPRESS PERMIT PROGRAM · Fire Alarm System FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101037716. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: NONE (EXEMPT) . SPECIFIC LOCATION: SUITE 1910. Status: Suspended | Anthony Bonilla | — |
| applied Oct 30 | #101061709 PERMIT - ELEVATOR EQUIPMENT REPLACE HOIST ROPES AND THE SHEAVE ON ONE (1) 4500LB.CAP, 26-FLOORS, 13-OPENINGS, GEARLESS TRACTION PASSENGER ELEVATOR #HR11. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV003622 | TK Elevator | $30K |